Reference Manual

00809-0100-4663, Rev BA January 2010

Rosemount 8732

HAZARDOUS LOCATIONS PRODUCT APPROVALS OFFERING

Table B-1. Factory Mutual (FM) Approvals Offering

The Rosemount 8700 Series magnetic flowmeters offer many different hazardous locations certifications. The table below provides an overview of the available hazardous area approval options. Equivalent hazardous locations certifications for sensor and transmitter must match in integrally mounted magnetic flowmeter systems. Remote mounted magnetic flowmeter systems do not require matched hazardous location certifications. For complete information about the hazardous area approval codes listed, see Hazardous Location Certifications starting on page B-5.

 

 

 

 

 

 

 

 

 

Transmitter

 

8732E

 

 

8712D(1)

 

8712H(1)

Sensor

8705

8707

8711

8705

8707

 

8711

8707

FM Category

 

Hazardous Area Approval Code

 

Non-Classified Locations

 

 

 

 

 

 

 

 

Transmitter

NA

NA

NA

NA

NA

 

NA

N0

Sensor

NA

N0

NA

NA

N0

 

NA

N0

Suitable for Class I, Division 1

 

 

 

 

 

 

 

 

Explosion-Proof

 

 

 

 

 

 

 

 

Trans: Groups C, D T6

E5(2)

-

E5

-

-

 

-

-

Sensor: Groups C, D T6

E5(2)

-

E5

-

-

 

-

-

Explosion-Proof with Intrinsically Safe Output

 

 

 

 

 

 

 

 

Trans: Groups C, D T6

E5(2)(3)

-

E5(3)

-

-

 

-

-

Sensor: Groups C, D T6

E5(2)

-

E5

-

-

 

-

-

Suitable for Class I, Division 2

 

 

 

 

 

 

 

 

Non-Flammable Fluids

 

 

 

 

 

 

 

 

Trans: Groups A,B,C,D T4

N0

N0

N0

N0

N0

 

N0

N0

Sensor: Groups A,B,C,D T5

N0

N0(4)

N0

N0

N0(4)

 

N0

N0(4)

Flammable Fluids

 

 

 

 

 

 

 

 

Trans: Groups A,B,C,D T4

N5

N5

N5

N5

N5

 

N5

N5

Sensor: Groups A,B,C,D T5

N5

N5(4)

N5

N5

N5(4)

 

N5

N5(4)

Non-Flammable Fluids with Intrinsically Safe Output

 

 

 

 

 

 

 

Trans: Groups A,B,C,D T4

N0(3)

N0(3)

N0(3)

-

-

 

-

-

Sensor: Groups A,B,C,D T5

N0

N0(4)

N0

-

-

 

-

-

Other Certifications

 

Product Certification Code(5)

 

European Pressure Equipment Directive (PED)

PD

-

PD

PD

-

 

PD

-

NSF 61 Drinking Water(6)

DW

-

DW

DW

-

 

DW

-

(1)Remote Transmitter Only

(2)Available in line sizes 0.5 in. to 8 in. (15 mm to 200 mm) only

(3)For I.S. Output, Output Code B must be ordered

(4)8707 Sensor has Temp Code - T3C

(5)Product Certification Codes are added to the Sensor model number only

(6)Only available with PTFE (all line sizes) or Polyurethane (4 in. or larger) Lining Materials and 316L SST Electrodes

Table B-2. Canadian Standards

Association (CSA) Approvals

Offering

 

 

 

 

 

 

 

 

 

Transmitter

 

8732E

 

 

8712D(1)

 

8712H(1)

Sensor

8705

8707

8711

8705

8707

 

8711

8707

CSA Category

 

Hazardous Area Approval Code

Non-Classified Locations

 

 

 

 

 

 

 

 

Transmitter

NA

-

NA

NA

-

 

NA

-

Sensor

NA

-

NA

NA

-

 

NA

-

Suitable for Class I, Division 2

 

 

 

 

 

 

 

 

Non-Flammable Fluids

 

 

 

 

 

 

 

 

Trans: Groups A,B,C,D T4

N0

N0

N0

N0

N0

 

N0

N0

Sensor: Groups A,B,C,D T5

N0

N0(2)

N0

N0

N0(2)

 

N0

N0(2)

Other Certifications

 

Product Certification Code(3)

 

European Pressure Equipment Directive (PED)

PD

-

PD

PD

-

 

PD

-

NSF 61 Drinking Water(4)

DW

-

DW

DW

-

 

DW

-

(1)Remote Transmitter Only

(2)8707 Sensor has Temp Code - T3C

(3)Product Certification Codes are added to the Sensor model number only

(4)Only available with PTFE (all line sizes) or Polyurethane (4 in. or larger) Lining Materials and 316L SST Electrodes