Reference Manual

00809-0100-4663, Rev BA January 2010

Rosemount 8732

Measured Reverse Total

Fast Keys

1, 1, 4, 4

Measured reverse total provides the output reading of the totalizer. This value is the amount of process fluid that has passed through the flowmeter in the reverse direction since the totalizer was last reset. This value is only totalized when reverse flow is enabled.

Pulse Output

Fast Keys

1, 1, 5

BASIC SETUP

Fast Keys

1, 3

Start Totalizer

Fast Keys

1, 1, 4, 5

Start totalizer starts the totalizer counting from its current value.

Stop Totalizer

Fast Keys

1, 1, 4, 6

Stop totalizer interrupts the totalizer count until it is restarted again. This feature is often used during pipe cleaning or other maintenance operations.

Reset Totalizer

Fast Keys

1, 1, 4, 7

Reset totalizer resets the net totalizer value to zero. The totalizer must be stopped before resetting.

NOTE

The totalizer value is saved in the Non-Volatile memory of the electronics every three seconds. Should power to the transmitter be interrupted, the totalizer value will start at the last saved value when power is re-applied.

The Pulse Output displays the current value of the pulse signal.

The basic configuration functions of the Rosemount 8732 must be set for all applications of the transmitter in a magnetic flowmeter system. If your application requires the advanced functionality features of the Rosemount 8732, see Section 4 "Operation" of this manual.

Tag

Fast Keys

1, 3, 1

 

 

Flow Units

Fast Keys

1, 3, 2

Tag is the quickest and shortest way of identifying and distinguishing between transmitters. Transmitters can be tagged according to the requirements of your application. The tag may be up to eight characters long.

Flow Units set the output units for the Primary Variable which controls the analog output of the transmitter.

Primary Variable Units

Fast Keys

1, 3, 2, 1

 

 

The Primary Variable Units specifies the format in which the flow rate will be displayed. Units should be selected to meet your particular metering needs.