Rosemount 8732

Reference Manual

00809-0100-4663, Rev BA January 2010

KENT SENSORS

Kent Sensor to Rosemount 8732 Transmitter

Connect coil drive and electrode cables as shown in Figure E-17.

Figure E-17. Generic Wiring Diagram for Kent Sensors and Rosemount 8732

Table E-18. Kent Sensor Wiring Connections

KENT SENSORS

ROSEMOUNT 8732

 

 

TRANSMITTER

 

SIG2

 

Electrodes

SIG1

 

 

SCR OUT

 

 

SCR OUT

 

Coils

2

 

 

1

 

 

 

Fuse

Rosemount 8732

 

Kent Sensors

1

 

 

1

2

 

 

2

 

 

 

 

 

 

SCR OUT

 

 

 

 

 

17

 

 

SCR OUT

18

 

 

SIG1

19

 

 

SIG2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is a pulsed DC magnetic flowmeter.

Do not connect AC power to the sensor or to terminals 1 and 2 of the transmitter, or replacement of the electronics board will be necessary.

E-20

Page 160
Image 160
Emerson Process Management manual Kent Sensor to Rosemount 8732 Transmitter, Coils Fuse, Rosemount Kent Sensors