Reference Manual

00809-0100-4663, Rev BA January 2010

Rosemount 8732

Table B-8. Relation between ambient temperature, process temperature, and temperature class(1)

 

 

Maximum Process

 

 

 

Temperature

Meter Size (Inches)

Maximum Ambient Temperature

Temperature

Class

1/2

115°F (65°C)

239°F (115°C)

T3

1

149°F (65°C)

248°F (120°C)

T3

1

95°F (35°C)

95°F (35°C)

T4

11/2

149°F (65°C)

257°F (125°C)

T3

11/2

122°F (50°C)

148°F (60°C)

T4

2

149°F (65°C)

257°F (125°C)

T3

2

149°F (65°C)

167°F (75°C)

T4

2

104°F (40°C)

104°F (40°C)

T5

3 - 36

149°F (65°C)

266°F (130°C)

T3

3 - 36

149°F (65°C)

194°F (90°C)

T4

3 - 36

131°F (55°C)

131°F (55°C)

T5

3 - 36

104°F (40°C)

104°F (40°C)

T6

6

115°F (65°C)

275°F(135°C)

T3

6

115°F (65°C)

230°F (110°C)

T4

6

115°F (65°C)

167°F (75°C)

T5

6

140°F (60°C)

140°F (60°C)

T6

8-60

115°F (65°C)

284°F (140°C)

T3

8-60

115°F (65°C)

239°F (115°C)

T4

8-60

115°F (65°C)

176°F (80°C)

T5

8-60

115°F (65°C)

156°F (69°C)

T6

Table B-9. Relation between the maximum ambient temperature, the maximum process temperature, and the temperature class(2)

 

 

 

 

 

Maximum Ambient

Maximum process temperature °F (°C) per temperature class

Temperature

T3

 

T4

T5

T6

 

 

0.5

in. sensor size

 

 

149°F (65°C)

297°F (147°C)

 

138°F (59°C)

54°F (12°C)

18°F (-8°C)

140°F (60°C)

309°F (154°C)

 

151°F (66°C)

66°F (19°C)

28°F (-2°C)

131°F (55°C)

322°F (161°C)

 

163°F (73°C)

79°F (26°C)

41°F (5°C)

122°F (50°C)

334°F (168°C)

 

176°F (80°C)

90°F (32°C)

54°F (12°C)

113°F (45°C)

347°F (175°C)

 

189°F (87°C)

102°F (39°C)

66°F (19°C)

104°F (40°C)

351°F (177°C)

 

199°F (93°C)

115°F (46°C)

79°F (26°C)

95°F (35°C)

351°F (177°C)

 

212°F (100°C)

127°F (53°C)

90°F (32°C)

86°F (30°C)

351°F (177°C)

 

225°F (107°C)

138°F (59°C)

102°F (39°C)

77°F (25°C)

351°F (177°C)

 

237°F (114°C)

151°F (66°C)

115°F (46°C)

68°F (20°C)

351°F (177°C)

 

248°F (120°C)

163°F (73°C)

127°F (53°C)

 

1.0 in. sensor size

 

 

 

 

 

 

 

 

149°F (65°C)

318°F (159°C)

 

158°F (70°C)

72°F (22°C)

34°F (1°C)

140°F (60°C)

331°F (166°C)

 

171°F (77°C)

84°F (29°C)

46°F (8°C)

131°F (55°C)

343°F (173°C)

 

183°F (84°C)

97°F (36°C)

59°F (15°C)

122°F (50°C)

351°F (177°C)

 

196°F (91°C)

109°F (43°C)

72°F (22°C)

113°F (45°C)

351°F (177°C)

 

207°F (97°C)

122°F (50°C)

84°F (29°C)

104°F (40°C)

351°F (177°C)

 

219°F (104°C)

135°F (57°C)

97°F (36°C)

95°F (35°C)

351°F (177°C)

 

232°F (111°C)

145°F (63°C)

109°F (43°C)

86°F (30°C)

351°F (177°C)

 

244°F (118°C)

158°F (70°C)

122°F (50°C)

77°F (25°C)

351°F (177°C)

 

257°F (125°C)

171°F (77°C)

135°F (57°C)

68°F (20°C)

351°F (177°C)

 

270°F (132°C)

183°F (84°C)

145°F (63°C)

(1)This table is applicable for CD and KD option codes only.

(2)This table is applicable for N1 option codes only.

B-13

Page 105
Image 105
Emerson Process Management 8732 manual In. sensor size