Reference Manual

Rosemount 8732

00809-0100-4663, Rev BA January 2010

Figure A-2. Apparent Power

 

38

 

 

 

 

 

 

 

 

 

(VA)

36

 

 

 

 

 

 

 

 

 

34

 

 

 

 

 

 

 

 

 

Power

32

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

Apparent

28

 

 

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

80

100

120

140

160

180

200

220

240

250

 

 

 

 

Power Supply Voltage (AC RMS)

 

 

 

 

DC Supply Current Requirements

Units powered by 12-42 V DC power supply may draw up to 1 amp of current steady state.

Figure A-3. DC Current Requirements

 

1

 

 

 

 

 

(Amps)

0.75

 

 

 

 

 

 

 

 

 

 

 

Current

0.5

 

 

 

 

 

 

 

 

 

 

 

Supply

0.25

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

12

18

24

30

36

42

Power Supply (Volts)

Installation Coordination

Installation (overvoltage) Category II

Power Consumption

10 watts maximum

Switch-on current

AC: Maximum 26 A (< 5 ms) at 250 V AC

DC: Maximum 30 A (< 5 ms) at 42 V DC

Ambient Temperature Limits

Operating

–58 to 165 °F (–50 to 74 °C) without local operator interface 13 to 149 °F (–25 to 65 °C) with local operator interface

Storage

–40 to 185 °F (–40 to 85 °C)

–22 to 176 °F (–30 to 80 °C) with local operator interface

Humidity Limits

0–100% RH to 150 °F (65 °C)