Rosemount 8732

Reference Manual

00809-0100-4663, Rev BA January 2010

North American Certifications

Factory Mutual (FM)

N0 Division 2 Approval for

Non-Flammable Fluids (All Sensors)

Class I, Division 2, Groups A, B, C, D

Temp Code – T5 (8705/8711 at 60°C) Temp Code – T3C (8707 at 60°C)

Dust-Ignition proof Class II/III, Division 1, Groups E, F, G Temp Code – T6 (8705/8711 at 60°C)

Temp Code – T3C (8707 at 60°C) Enclosure Type 4X

N0 for 8721 Hygienic Sensor

Factory Mutual (FM) Ordinary Location;

CE Marking; 3-A Symbol Authorization #1222;

EHEDG Type EL

N5 Division 2 Approval for Flammable Fluids (All Sensors)

Class I, Division 2, Groups A, B, C, D

Temp Code – T5 (8705/8711 at 60°C) Temp Code – T3C (8707 at 60°C)

Dust-Ignition proof Class II/III, Division 1, Groups E, F, G Temp Code – T6 (8705/8711 at 60°C)

Temp Code – T3C (8707 at 60°C) Enclosure Type 4X

E5 Explosion-Proof (8705 and 8711 Only)

Explosion-Proof for Class I, Division 1, Groups C, D Temp Code – T6 at 60°C

Dust-Ignition proof Class II/III, Division 1, Groups E, F, G Temp Code – T6 at 60°C

Class I, Division 2, Groups A, B, C, D Temp Code – T5 at 60°C

Enclosure Type 4X

Canadian Standards Association (CSA)

N0 Suitable for Class I, Division 2, Groups A, B, C, D Temp Code – T5 (8705/8711 at 60°C)

Temp Code – T3C (8707 at 60°C)

Dust-Ignition proof Class II/III, Division 1, Groups E, F, G Enclosure Type 4X

N0 for 8721 Hygienic Sensor

Canadian Standards Association (CSA) Ordinary Location;

CE Marking; 3-A Symbol Authorization #1222;

EHEDG Type EL

European Certifications

ND ATEX Dust

8732 - Certificate No.: KEMA 06ATEX0006 II 1D max

T = 40 °K(1) Amb. Temp. Limits: (-20 °C = Ta = +65 °C) Vmax = 40 V DC (pulsed)

IP 66 CE 0575

N1 ATEX Non-Sparking/Non-incendive (8705/8711 Only)

Certificate No: KEMA02ATEX1302X II 3G

EEx nA [L] IIC T3... T6

Ambient Temperature Limits -20 to 65°C

B-10

Page 102
Image 102
Emerson Process Management 8732 N0 Division 2 Approval for Non-Flammable Fluids All Sensors, N0 for 8721 Hygienic Sensor