Rosemount 8732

Reference Manual

00809-0100-4663, Rev BA January 2010

ENDRESS AND HAUSER SENSORS

Endress and Hauser Sensor to Rosemount 8732 Transmitter

Figure E-5. Wiring Diagram for Endress and Hauser Sensors and Rosemount 8732

Connect coil drive and electrode cables as shown in Figure E-5.

ROSEMOUNT 8732

TRANSMITTER

ENDRESS AND HAUSER

SENSORS

41

Coils 42

4

Electrodes 5

7

Table E-6. Endress and Hauser Sensor Wiring Connections

Rosemount 8732

 

Endress and Hauser Sensors

1

41

2

42

 

14

 

 

 

17

4

18

5

19

7

 

 

 

 

 

 

This is a pulsed DC magnetic flowmeter.

Do not connect AC power to the sensor or to terminals 1 and 2 of the transmitter, or replacement of the electronics board will be necessary.

E-8

Page 148
Image 148
Emerson Process Management manual Endress and Hauser Sensors, Endress and Hauser Sensor to Rosemount 8732 Transmitter