Rosemount 8732

Reference Manual

00809-0100-4663, Rev BA January 2010

Table B-7. Electrical Data

Rosemount 8732 Flow Transmitter

Power supply:

250 V AC, 1 A or 42 Vdc, 2,5 A, 20 W maximum

Foundation fieldbus

30 V DC, 30 mA, 1 W maximum

output:

 

Rosemount 8705 and 8711 Sensors

 

 

Coil excitation

40 V DC (pulsed), 0,5 A, 20 W maximum

circuit:

 

Electrode circuit:

Intrinsically Safe Electrode Circuit: Ui = 5 V, li = 0.2 mA, Pi = 1 mW,

 

Um = 250 V

Rosemount 8732E Flow Transmitter:

 

 

Power supply:

250 V AC, 1 A or 42 Vdc, 2, 5 A, 20 W maximum

FOUNDATION

Intrinsically Safe Output:

fieldbus output:

 

Ui = 30 V

 

Ii = 380 mA

 

Pi = 5,32 W

 

Ci = 924 pF

 

Li = 0 mH

B-12

Page 104
Image 104
Emerson Process Management 8732 manual 00809-0100-4663, Rev BA January Table B-7. Electrical Data