Rosemount 8732

Reference Manual

00809-0100-4663, Rev BA January 2010

Figure 3-1. Local Operator

Interface Keypad

Data Entry

The LOI keypad does not have numerical keys. Numerical data is entered by

 

the following procedure.

 

1.

Access the appropriate function.

 

2.

Use the RIGHT ARROW key to move to the value to change.

 

3.

Use the UP and DOWN ARROWS to change the highlighted value.

 

 

For numerical data, toggle through the digits 0–9, decimal point, and

 

 

dash. For alphabetical data, toggle through the letters of the alphabet

 

 

A–Z, digits 0–9, and the symbols ,&, +, -, *, /, $, @,%, and the blank

 

 

space.

 

4.

Use the RIGHT ARROWS to highlight other digits you want to change

 

 

and change them.

 

5.

Press “E” (the left arrow key) when all changes are complete to save

 

 

the entered values.

LOI EXAMPLES

Use the DOWN ARROW to access the menu structure in Table 3-2. Use the

 

ARROW KEYS to select the desired parameters to review/change.

 

Parameters are set in one of two ways, Table Values or Select Values.

Table Values:

Parameters such as units, that are available from a predefined list

Select Values:

Parameters that consist of a user-created number or character string, such as calibration number; values are entered one character at a time using the ARROW KEYS.

3-2