Rosemount 8732

Reference Manual

00809-0100-4663, Rev BA January 2010

PARAMETERS AND DESCRIPTIONS

Table G-1. Transducer Block Parameters

Table G-1lists all of the configurable parameters of the transducer block, indicating the descriptions and index numbers for each parameters.

Parameter

Index Number

Definition

ALERT_KEY

4

ID number of the transmitter–may be used on the host for sorting alarms

BLOCK_ALM

8

Block alarm

COIL_DRIVE_FREQ

35

Frequency at which the coils are being driven (5 or 37.5 Hz)

DAMPING

30

Damping filter value (in seconds)

DENSITY_UNIT

31

Unit code associated with DENSITY_VALUE. Valid values are lb/cubic feet, or

 

 

kg/cubic meter

DENSITY_VALUE

75

User entered density value to be used by the transducer block when calculating flow

 

 

rate in mass flow units

DIAGNOSTIC_HANDLING

60

On/Off handling for diagnostics

ELECTRODE_MATERIAL

51

Enumerated string indicating flange material of installed flowtube

ELECTRODE_TYPE

52

Enumerated string indicating electrode type of installed flowtube

EP_TRIG_COUNTS

40

Number of EP measurements that must be above the trigger level to set empty pipe

EP_TRIG_LEVELS

41

Empty Pipe Trigger Levels

FLANGE_MATERIAL

54

Enumerated string indicating liner material of installed flowtube

FLANGE_TYPE

53

Enumerated string indicating liner material of installed flowtube

FLOW_TUBE_SERIAL_NUMBER

49

Flow tube serial number from physical tag on flowtube

FLOW_TUBE_TAG

48

Text String Identifier of flowtube

LICENSE_KEY

78

Key/password to enable diagnostic features. Any changes to the licensing will be

 

 

shown in the LICENSE_STATUS parameter

LINER_MATERIAL

50

Enumerated string indicating liner material of installed flowtube

LOI_LANG

39

Selects the language to be used in the local display for status and diagnostics

 

 

messages

LOW_FLOW_CUTOFF

37

When flow rate is less than this entered value, flow rate output will be set to 0 ft/s

MODE_BLK

5

Mode of the record of the block–contains the actual, target, permitted,

 

 

and normal modes

SENSOR_CAL_DATE

25

Date of the last sensor calibration–intended to reflect the calibration of the sensor

SENSOR_CAL_LOC

24

Location of the last sensor calibration–describes the physical location at which the

 

 

calibration was performed

SENSOR_CAL_METHOD

23

Method of the last sensor calibration–ISO defines several standard methods of

 

 

calibration (This parameter is intended to record that method or if some other method

 

 

was used.)

SENSOR_CAL_WHO

26

Name of the person responsible for the last sensor calibration

STATUS_MESSAGE_MFG

61

Used by manufacturing to test groups to simulate status codes

STRATEGY

3

Can be used to help group the blocks (Not checked or processed by the block)

TAG_DESC

2

Static tag–ASCII character string

TUBE_CAL_NO

33

Sensor gain and zero offset number used in flow calculation

 

 

(Number entered is locate on physical tag of the sensor.)

TUBE_SIZE

34

Tube Size. See Tube Size for actual line sizes

UPDATE_EVT

7

Update event

G-2

Page 174
Image 174
Emerson Process Management 8732 manual Parameter Index Number Definition, Densityvalue