Rosemount 8732
Reference Manual
00809-0100-4663, Rev BA January 2010
8714i Results
375 Transducer Block, Diagnostics, Advanced Diagnostics, 8714i Meter Verification
Review the results of the most recently performed 8714i Meter Verification test. Information in this section details the measurements taken and if the meter passed the verification test. For more details on these results and what they mean, see Appendix C: Diagnostics.
Test Condition
375Transducer Block, Diagnostics, Advanced Diagnostics, 8714i Meter Verification, 8714i Results
Displays the conditions that the 8714i Meter Verification test was performed under. For more details on this parameter see Appendix C: Diagnostics.
Test Criteria
375Transducer Block, Diagnostics, Advanced Diagnostics, 8714i Meter Verification, 8714i Results
Displays the criteria that the 8714i Meter Verification test was performed against. For more details on this parameter see Appendix C: Diagnostics.
8714i Result
375Transducer Block, Diagnostics, Advanced Diagnostics, 8714i Meter Verification, 8714i Results
Displays the results of the 8714i Meter Verification test as pass or fail. For more details on this parameter see Appendix C: Diagnostics.
Simulated Velocity
375Transducer Block, Diagnostics, Advanced Diagnostics, 8714i Meter Verification, 8714i Results
Displays the test velocity used to verify transmitter calibration. For more details on this parameter see Appendix C: Diagnostics.
Actual Velocity
375Transducer Block, Diagnostics, Advanced Diagnostics, 8714i Meter Verification, 8714i Results
Displays the velocity measured by the transmitter during the transmitter calibration verification test. For more details on this parameter see Appendix C: Diagnostics.
Velocity Deviation
375Transducer Block, Diagnostics, Advanced Diagnostics, 8714i Meter Verification, 8714i Results
Displays the deviation of the transmitter calibration verification test. For more details on this parameter see Appendix C: Diagnostics.
Transmitter Calibration Result
375Transducer Block, Diagnostics, Advanced Diagnostics, 8714i Meter Verification, 8714i Results
Displays the result of the transmitter calibration verification test as pass or fail. For more details on this parameter see Appendix C: Diagnostics.
Sensor Calibration Deviation
375Transducer Block, Diagnostics, Advanced Diagnostics, 8714i Meter Verification, 8714i Results
Displays the deviation of the sensor calibration verification test. For more details on this parameter see Appendix C: Diagnostics.