Reference Manual

00809-0100-4663, Rev BA January 2010

Rosemount 8732

YOKOGAWA SENSORS

Yokogawa Sensor to Rosemount 8732 Transmitter

Connect coil drive and electrode cables as shown in Figure E-22.

Figure E-22. Generic Wiring Diagram for Yokogawa Sensors and Rosemount 8732

YOKOGAWA

ROSEMOUNT 8732

SENSORS

TRANSMITTER

Electrodes

A

B

 

 

C

Chassis Ground

Coils

Ex 2

 

Ex 1

 

Fuse

Table E-23. Yokogawa Sensor Wiring Connections

Rosemount 8732

 

Yokogawa Sensors

1

 

 

 

EX1

2

 

 

 

EX2

 

 

 

 

 

 

Chassis Ground

 

 

 

 

 

17

 

 

C

18

 

 

B

19

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is a pulsed DC magnetic flowmeter.

Do not connect AC power to the sensor or to terminals 1 and 2 of the transmitter, or replacement of the electronics board will be necessary.

E-25

Page 165
Image 165
Emerson Process Management manual Yokogawa Sensor to Rosemount 8732 Transmitter, Rosemount Yokogawa Sensors