VHX SERIES STEAMER - TROUBLESHOOTING
SYMPTOM |
| POSSIBLE CAUSES |
|
|
|
Condenser drain box leaking. | 1. | Grommets or cover panel gasket not sealing. |
| 2. | Clog in drain line plumbing. |
| 3. | Drain restricted due to drain pipe size below |
| 4. | Drain extension plumbing not at the proper slope or plumbing |
|
| too lengthy. |
| 5. | Steamer drain not plumbed to an open air gap drain. |
| 6. | Steamer draining while under pressure and relief valve opening |
|
| at the same time (flooding drain box). |
| 7. | Cold water condenser spray is over spraying. |
| 8. | Cold water condenser cycling thermostat out of adjustment or |
|
| malfunction. |
|
|
|
Excessive steam vapors exiting from | 1. | Water supply for cold water condenser line off or inline strainer |
drain. |
| clogged. |
| 2. | Cold water condenser solenoid not receiving power, clogged or |
|
| malfunction. |
| 3. | Clogged spray nozzle (condenser drain box). |
| 4. | Water supply pressure high; or high pressure in line due to |
|
| water hammer, causing improper valve operation. |
| 5. | Cold water condenser thermostat out of adjustment or |
|
| malfunction. |
|
|
|
Heat coming on without water in boiler | 1. | Lime scale |
(Dry firing). | 2. | Retention of water in probe housing (three probe assembly or |
|
| single AUX LLCO probe). |
| 3. | Air equalization tubes clogged. |
| 4. | Water level control malfunction. |
| 5. | Auxiliary water level control malfunction. |
| 6. | Reset switch malfunction. |
| 7. | K1, K2, K3, K4 relays malfunction. |
| 8. | Relay board malfunction. |
|
|
|
Excessive time for boiler to reach | 1. | Supply voltage incorrect. |
operating pressure (over 15 min.). | 2. | Heating elements not wired correctly. |
| 3. | Contactor(s) malfunction. |
| 4. | Water supply off or low pressure, filtering system clogged, |
|
| boiler fill valve clogged or malfunction. |
| 5. | Manual blowdown valve on water level probe housing open. |
| 6. | Boiler blowdown/drain solenoid valve clogged and not fully |
|
| closing. |
| 7. | Steam trap malfunction (stuck open). |
| 8. | Pressure relief valve leaking (pressure below 15PSI). |
| 9. | Cooking compartment steam solenoid valve clogged and not |
|
| fully closing. |
| 10. | Excessive load on boiler due to other equipment connected to |
|
| steam line (outlet from boiler). |
| 11. | A heavy |
|
| boiler, creating an insulating effect. |
|
|
|