VHX SERIES STEAMER - TROUBLESHOOTING
TROUBLESHOOTING
BOILER BASE CONTROLS
SYMPTOM |
| POSSIBLE CAUSES |
|
|
|
Steamer does not operate, low water light | 1. | Main circuit breaker off; or control circuit fuse F1 or F2 open. |
and high pressure lights not lit. | 2. | Supply voltage incorrect. |
| 3. | Supply voltage transformer - jumper missing or incorrect |
|
| location; or transformer inoperative. |
| 4. | Power switch malfunction. |
|
|
|
Steamer on, cannot reset low water | 1. | Boiler fill water off or filtering system clogged. |
condition. Low water light lit, ready light | 2. | Boiler blowdown/drain valve stuck open or malfunction. |
not lit, water level not visible in sight glass. | 3. | Manual blowdown valve open on water level probe housing. |
| ||
| 4. | Lime scale |
| 5. | Water level control board - ground connection open, not |
|
| receiving power or malfunction. |
| 6. | Boiler fill valve clogged or malfunction. |
| 7. | Auxiliary water level control board - ground connection open, |
|
| not receiving power or malfunction. |
| 8. | Reset switch malfunction. |
| 9. | K1, K3 relays not seated properly or malfunction. |
| 10. | Water too pure for probes to properly conduct electricity. |
| 11. | Interconnecting wiring malfunction. |
|
|
|
Steamer on, cannot reset low water | 1. | Ground connection open on auxiliary water level control board. |
condition. Low water light lit, ready light | 2. | Lime scale |
not lit, water level visible in sight glass. | 3. | Auxiliary water level control board not receiving power or |
| ||
|
| malfunction. |
| 4. | Reset switch malfunction. |
| 5. | K1, K3 relays not seated properly or malfunction. |
| 6. | Interconnecting wiring malfunction. |
|
|
|
Steamer on, cannot reset high pressure | 1. | Cycling pressure switch out of adjustment or malfunction. |
condition. High pressure light lit, pressure | 2. | High limit pressure switch out of adjustment or malfunction. |
gauge indicating 15PSI. | 3. | Reset switch malfunction. |
| ||
| 4. | K2, K4 relays not seated properly or malfunction. |
| 5. | Steam trap malfunction. |
| 6. | Interconnecting wiring malfunction. |
|
|
|
Boiler operates but pressures are below | 1. | Manual blowdown valve on water level probe housing open. |
the normal cycling range of | 2. | Boiler blowdown valve clogged and not fully closing. |
| 3. | Supply voltage incorrect. |
| 4. | Cycling pressure switch out of adjustment or malfunction. |
| 5. | Heating elements not wired correctly. |
| 6. | Contactor(s) malfunction. |
| 7. | Heating element malfunction. |
| 8. | Steam trap malfunction. |
| 9. | Excessive load on boiler due to other equipment connected to |
|
| steam line (outlet from boiler). |
|
|
|
F25154 (February 2004) |