VHX SERIES STEAMERS - COMPONENT FUNCTION
Electrical
|
| TOTAL |
| AMPERAGE |
| ||
| MODELS |
|
|
|
|
| |
| 1 PHASE | 3 PHASE | |||||
|
| KW |
|
|
|
|
|
|
|
| 208V | 240V | 208V | 240V | 480V |
|
|
|
|
|
|
|
|
| VHX24E, | 24 | 116 | 100 | 67 | 58 | 29 |
|
|
|
|
|
|
| |
| 36 | 100 | 87 | 44 | |||
| VHX24E5, | ||||||
|
|
|
|
|
|
| |
| 42 | 117 | |||||
| MHB24E | ||||||
| 48 | 116 | 58 | ||||
|
| ||||||
|
|
|
|
|
|
|
|
NOTES: 1. Amperage values in the table are nominal. Tolerance is
2.Voltage values are @ 60HZ.
3.24KW 3 phase is standard for both models. If a 24KW single phase connection is needed, the machine is
field convertible at the terminal block. See heating element circuit diagram AI1388.
TOOLS
Standard
!Standard set of hand tools.
!VOM with AC current tester.
NOTE: Any quality VOM with a sensitivity of at least 20,000 ohms per volt can be used.
Special
!The recommended deliming chemical for the water treatment system in use, for deliming of the boiler.
!Heat Exchanger Gasket (joint sealant strip, Teflon) P/N
!Loctite 242 thread sealant or equivalent P/N 520228. Used on the top and bottom cooking compartment door screws.
!3/8 x 16 tap. Used for cleaning out threads on front boiler flange.