VHX SERIES STEAMER - TROUBLESHOOTING
SYMPTOM |
| POSSIBLE CAUSES |
|
|
|
Steamer on, boiler will not heat. Reset | 1. | Reset switch malfunction. |
switch activated, low water light and high | 2. | Water Level Control malfunction. |
pressure light not lit, ready light lit. | 3. | Cycling pressure switch out of adjustment or malfunction. |
| ||
| 4. | High limit pressure switch out of adjustment or malfunction. |
| 5. | K3, K4 relays malfunction. |
| 6. | Relay board malfunction. |
| 7. | Contactor(s) malfunction. |
| 8. | Interconnecting wiring malfunction. |
|
|
|
Pressure relief valve opening or leaking. | 1. | Pressure relief valve malfunction. |
| 2. | Cycling pressure switch out of adjustment or malfunction. |
| 3. | High limit pressure switch out of adjustment or malfunction. |
|
|
|
Steam output low or slow cooking. | 1. | Cooking Compartments. |
|
| A. Blocked steam injector ports. Open door, press door switch |
|
| button and verify good steam flow into compartment. |
|
| B. Steam solenoid valve clogged or malfunction. |
|
| C. Steam intake |
| 2. | Boiler Base. |
|
| A. Cycling pressure switch out of adjustment or malfunction. |
|
| B. Steam header line (supply) blockage. |
|
| C. Excessive amount of water in condensate tube loop from |
|
| boiler to pressure controls. |
|
| D. Pressure relief valve leaking. |
|
| E. Excessive steam supply line leaks. |
|
|
|
Steamer leaks water. | 1. | Water, steam or drain line connections loose (top or base). |
| 2. | Heating element gasket not sealing. |
| 3. | Heating element mounting plate not sealing. |
| 4. | Gauge glass fittings loose. |
|
|
|
Boiler water level too high, more than 1" | 1. | Boiler fill valve malfunction. |
visible in sight glass. | 2. | Water level probes not wired correctly. |
| 3. | Lime scale |
| 4. | Water level control malfunction. |
|
|
|
Boiler does not fill or is slow to fill. | 1. | Boiler fill water off or filtering system clogged. |
| 2. | Manual blowdown valve on water level probe housing open. |
| 3. | Boiler fill valve not receiving power, clogged or malfunction. |
| 4. | Boiler blowdown/drain valve clogged and not fully closing. |
| 5. | Air equalization tubes clogged. |
| 6. | Water level control malfunction. |
|
|
|
F25154 (February 2004) |
| Page 44 of 48 |
|