Vulcan-Hart C24EA3 480V PRO, C24EA5 480V BASIC Electrical Operation, Component Function

Page 36

MODEL C24EA - ELECTRICAL OPERATION

ELECTRICAL OPERATION

COMPONENT FUNCTION

Water Level Control (WLC) Board

Controls water level by monitoring conditions of the three water

 

level probes H, L and LLCO.

Buzzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Creates audible signal when timed cook cycle is complete.

Contactor, Limiting . . . . . . . . . . . . . . . . . . . . . Connects one side of heating elements to incoming power. Energized whenever WLC (LLCO) coil is energized.

Contactor, Regulating . . . . . . . . . . . . . . . . . . . Connects one side of heating elements to power. On constantly during cooking cycle.

Drain Valve, Motorized (Ball type) . . . . . . . . . . (Professional models only) Motorized control for opening and closing drain valve.

Element, Heating

Located in steam generator tank. Heats water to produce steam.

Element, Super-heater

(Professional models only) Located in piping from steam

 

generator tank to cooking chamber. Provides additional energy

 

to raise steam temperature.

Fuse, (1FU)

Slow blow 4A fuse. Located on primary side of main

 

transformer. Protects control circuitry from over-currents.

Fuse, (2FU)

Slow blow 4A fuse. Located on primary side of main

 

transformer. Protects control circuitry from over-currents.

Lamp (3LT), Power . . . . . . . . . . . . . . . . . . . . .

Lamp (2LT), Cook . . . . . . . . . . . . . . . . . . . . . .

Lamp (1LT), Ready . . . . . . . . . . . . . . . . . . . . .

Amber (AM) colored lamp. On when power switch is on.

Red (RD) colored lamp (Professional models only). On when hold thermostat is satisfied and door is closed and timer is set.

Green (GN) colored lamp (Professional models only). On when cycling thermostat is satisfied. Latches on when hold thermostat is satisfied.

Probe (H) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High water level probe connected to internal latch relay circuit. Water must reach this level before internal latch relay is energized.

Probe (L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Low water level probe connected to internal latch relay circuit.

Probe (LLCO) . . . . . . . . . . . . . . . . . . . . . . . . . . Low Level Cut-Off (LLCO) probe. Controls power to heating and timer circuitry. Controls fast fill solenoid (Professional models only).

Relay (K1)

Controlled by hold thermostat. Enables timer circuit.

Relay (K2), LLCO

Low Level Cut-Off (LLCO) external relay. Only energized during

 

drain. Controls Flush, Fast Fill and Vacuum Relief solenoids.

Relay (K3), Drain Relay . . . . . . . . . . . . . . . . . . Controlled by Time Delay Relay. Only energized during drain cycle. Controls WLC board and LLCO relay K2 during drain. Disables heating and timer circuitry.

Relay (K4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Professional models only) Latches Ready light on. Allows power to superheater.

Relay, Time Delay

Controlled by the power switch. Output becomes active for 90

 

seconds when power switch is turned to off. Only used during

 

drain cycle.

Solenoid (1SOL), Cooling . . . . . . . . . . . . . . . . Controlled by the condensate thermostat. Mixes cold water with hot condensate water from cooking chamber to reduce water temperature at drain.

Solenoid (2SOL), Flush . . . . . . . . . . . . . . . . . . On only during drain cycle. Mixes cold water with tank water before entering drain box. Keeps drain hose clear of debris.

Solenoid (3SOL), Fast Fill . . . . . . . . . . . . . . . . Initial tank fill for Professional machines. Used during last stage of drain cycle to flush drain opening free of debris.

F25213 (May 2006)

 

Page 36 of 52

 

Image 36
Contents C24EA Series Atmospheric Steamers C24EA3 Basic ShownTable of Contents General IntroductionModels Covered Steam CookingSpecifications 208V 240V 480VWater Conditioning Reference Material LubricationTools Component Lubrication TypeCovers and Panels Right and Left Side PanelsTOP Cover Model C24EA Covers and PanelsRear Panel Screw LocationTOP Cover Removed for Clarity Door RemovalGasket Model C24EA DoorInstallation Door HandleRemoval Latch Assembly Removal and DisassemblyAssembly Door Latch Adjustment Hinge BearingsOpening a Jammed Door Removal and Replacement AdjustmentDrain BOX Model C24EA Drain BOXCooking Compartment Model C24EA Cooking CompartmentProfessional Model Shown Model C24EA Cooking Compartment Thermostats Hold ThermostatHIGH-LIMIT Thermostat Model C24EA ThermostatsCondensate Thermostat Timer Model C24EA TimerCovers and Panels Professional Model Shown Heating Element Model C24EA Heating ElementBasic Model Shown Diagnostic Checks Overhead View of Heating ElementTotal kW Super Heater Model C24EA Super HeaterCurrent Resistance Ohms Water Level Control Components Water Level ControlsModel C24EA Water Level Control Components Low Level Cut-Off & Differential ControlWiring Water Level Control BoardWater Level Probes Water Level ControllerModel C24EA Water Level Control Components Cleaning Filtered and NON-FILTERED Water Solenoid ValvesValve Type Machine Flow Rate GPM Fast Flow Filtered Water Solenoid ValveManual Drain Valve Basic Non-Filtered Cold Water Solenoid ValveCovers and Panels View from Left Side of Steamer Motorized Drain Valve Professional Drain Tank ManuallyModel C24EA Water Level Control Components SWITCHES, Buzzer and Solenoids ON/OFF SwitchBasic Model On/Off Switch Check Switch Actuation Basic Model On/Off Switch AdjustmentDoor Switch Professional ModelsPressure Switch Check Typical Operating PressureVacuum Relief Solenoid Damage to generator tank weldment could occurBuzzer Steam Generator Tank Model C24EA Steam Generator TankPressure Switch Electrical Operation Component FunctionSwitch 1S, Power Switch 2S, DoorSwitch 1PAS, Pressure Timer 1TRComponent Location Electrical Control PanelWater Level Control Board Front Panel Steam Generator and Back Panel Sequence of Operation Basic ModelProfessional Model Model C24EA Electrical Operation Wiring Diagrams Heating Element WiringModel C24EA Electrical Operation Model C24EA Electrical Operation Model C24EA Electrical Operation Model C24EA Electrical Operation Troubleshooting Model C24EA TroubleshootingT E S Condensed Spare Parts List Model C24EA Condensed Spare Parts ListBasic Professional Qty

C24EA5 208/240V BASIC, C24EA3 480V BASIC, C24EA5 208/240V PRO, C24EA3 480V PRO, C24EA3 208/240V BASIC specifications

Vulcan-Hart is a renowned name in the commercial kitchen equipment industry, known for producing high-quality cooking appliances. Among their range of products, the Vulcan-Hart C24EA series stands out for its versatile and efficient electric convection ovens. The C24EA5 and C24EA3 models come in varying power configurations, catering to different operational needs.

The C24EA5 480V BASIC and PRO versions offer a robust solution for high-volume cooking. The BASIC model is designed for establishments seeking an economical yet effective option, while the PRO variant incorporates advanced features for enhanced performance. Both models operate at 480 volts, allowing them to work efficiently in larger commercial kitchens with higher power supply availability. They are equipped with an efficient heating system, ensuring consistent cooking temperatures and reduced energy consumption.

On the 208/240V side, the C24EA3 BASIC and PRO models provide flexibility for kitchens with lower voltage supply. These ovens deliver reliable performance while maintaining energy efficiency. The BASIC model offers essential functionalities suitable for smaller establishments, whereas the PRO model includes features such as programmable controls and a digital display for precision cooking and ease of use.

All models in the C24EA series are constructed with durable stainless steel exteriors, ensuring longevity and ease of cleaning. The ovens feature convection heating, which circulates hot air for even cooking results. This technology allows for a variety of cooking methods, from baking to roasting, making it a versatile choice for diverse kitchen needs.

Key features include multiple cooking racks for simultaneous baking, a temperature range that accommodates various recipes, and a user-friendly control panel that allows chefs to set and monitor cooking times efficiently. Additionally, the ovens are designed with safety features like cool-touch doors and durability in high-traffic environments.

Overall, the Vulcan-Hart C24EA series offers a range of electric convection ovens that combine reliability, efficiency, and versatility, making them ideal for any commercial kitchen looking to enhance its culinary capabilities. Whether on the 480V or 208/240V power supply, these ovens ensure optimal performance tailored to the specific needs of different food service operations.