Trane YCZ035F1, YCZ036F1/3M0B manual General Information, Inspection

Page 2

GENERAL INFORMATION

IMPORTANT: Read this entire manual before beginning installation procedures.

WARNING: BODILY INJURY CAN RESULT FROM HIGH VOLTAGE ELECTRICAL COMPONENTS, FAST MOVING FANS, AND COMBUSTIBLE GAS. FOR PROTECTION FROM THESE INHERENT HAZARDS DURING INSTALLATION AND SERVICING, THE ELECTRICAL SUPPLY MUST BE DISCONNECTED AND THE MAIN GAS VALVE MUST BE TURNED OFF. IF OPERATING CHECKS MUST BE PERFORMED WITH THE UNIT OPERATING, IT IS THE TECHNICIANS RESPONSIBILTY TO RECOGNIZE THESE HAZARDS AND PROCEED SAFELY.

Read this manual carefully before attempting to install, operate, or perform maintenance on this unit. Installation and mainte- nance should be performed by qualified service technicians only.

As shipped from the factory, this unit is for use with natural gas only, and is listed by Underwriters Laboratory.

Model YCY-F heating/cooling units are designed for outdoor mounting with a vertical condenser discharge. They can be located either at ground level or on a roof, in accordance with local codes or National Fuel Gas Code (ANSI-Z223.1A) Latest Revision. Since these units are designed exclusively for outdoor operation, additional flue venting systems are not required. Each unit contains an operating charge of Refrigerant-22 as shipped.

INSPECTION

1.Check for damage after the unit is unloaded. Report promptly, to the carrier, any damage found to the unit. Do not drop the unit.

IMPORTANT: The use of “spreader bars” is required when hoisting the unit (to prevent damage to sides and top).

IMPORTANT: DO NOT CONNECT GAS PIPING TO THE UNIT UNTIL A LINE PRESSURE TEST HAS BEEN COMPLETED. DAMAGE TO THE GAS VALVE MAY RESULT IN AN UNSAFE CONDITION. THIS UNIT SHOULD NEVER BE EXPOSED TO GAS LINE PRESSURE IN EXCESS OF 14 INCHES WATER COLUMN. (1/2 PSIG)

IMPORTANT: RECONNECT ALL GROUNDING DEVICES. ALL PARTS OF THIS PRODUCT CAPABLE OF CONDUCTING ELECTRICAL CURRENT ARE GROUNDED. IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS NUTS OR WASHERS USED TO COMPLETE A PATH TO GROUND ARE REMOVED FOR SERVICE, THEY MUST BE RETURNED TO THEIR ORIGI- NAL POSITION AND PROPERLY FASTENED.

IMPORTANT: ALL POWER LEGS MAY NOT BE BROKEN BY CONTACTORS. SEE WIRING DIAGRAM ON UNIT CONTROL BOX COVER.

THIS UNIT, AS SHIPPED FROM THE FACTORY, IS DE- SIGNED FOR NATURAL GAS ONLY.

BEFORE STARTING THE COMPRESSOR, THE CRANKCASE HEATER SHOULD BE ENERGIZED FOR EIGHT HOURS

The following warning complies with State of California law, Proposition 65.

2.Check the unit’s nameplate to determine if the unit is correct for the intended application. The power supply must be adequate for both the unit and all accessories.

3.Check to be sure the refrigerant charge has been retained during shipment. Access to 1/4" flare pressure taps may be gained by removing the furnace compartment access panel.

WARNING: Hazardous Gasses! Exposure to fuel substances or by-products of incomplete fuel combustion is believed by the state of California to cause cancer, birth defects, or other reproductive harm.

NOTICE

Warnings and Cautions appear at appropriate locations throughout this manual.

Read these carefully.

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices and where property-damage-only accidents could occur.

Page 2

Image 2
Contents ALL phases of this installation must comply with NATIONAL, State and Local CodesGeneral Information InspectionYCZ036,050,060F Models Typical Rooftop Installation with Full Perimeter CurbsTypical Rooftop Installation with BAYCURB030A,038A Model Dimensional DataYCZ036,050,060F Outline Back YCZ036,050,060F Outline Front TOPConverting Horizontal to Downflow Roof Penetration Hole Size RequiredClearances Locations and RecommendationsHorizontal Airflow Application Downflow Application -- Curb MountingLocation and Clearances InstallationUnit Support Placing and Rigging Placing the Unit on a Mounting Curb YCZ036,060F Models Typical Rooftop Application with FrameYCZ036,050,060F Rooftop -- UnitsTypical Condensate Drain Piping Condensate Drain PipingTypical Ground Level Application Ground Level -- Horizontal UnitsAttaching Downflow Ductwork to Roof Curb Precautionary MeasuresDuctwork Attaching Horizontal Ductwork to UnitSchematic Diagram GAS Piping to Unit GAS Piping InstallationGAS Pressure Setup Precautions Pipe Delivery ScheduleManifold Pressure Burner & Valve IllustrationFlue and Hood Illustration GAS Flow in Cubic Feet PER Hour Cubic Foot Dial High Altitude InstallationInput Check and Adjustment Filter Installation Electrical WiringYCZ-F Field Wiring Diagram Start UP Sequence of Operation Starting the Unit in the GAS Heating ModeSafety Sequences Heating CycleCooling Cycle ICM FAN Motor AdjustmentsCFM ICM FAN Controldip Indoor Blower TimingRefrigerant Circuit Checkout ProcedureSystem Faults ElectricalMaintenance Limited Warranty Combination GAS Electric AIR Conditioner YCZ, YCY and YCXCombination GAS Electric AIR Conditioner YCZ, YCY, YCX, YCC, YCD, YCH, YCP, YHC and YSC

YCZ036F1/3M0B, YCZ035F1 specifications

The Trane YCZ035F1 and YCZ036F1/3M0B are cutting-edge packaged rooftop units designed for commercial applications, delivering reliable heating, ventilation, and air conditioning (HVAC) solutions. These units exemplify state-of-the-art technology, ensuring energy efficiency, environmentally friendly operation, and superior performance.

One of the most prominent features of the Trane YCZ036F1/3M0B is its robust design that accommodates various building requirements. The flexible configurations allow for easy installation and adaptability to different applications, reducing the complexity often associated with rooftop HVAC solutions. Available in multiple capacities, these units cater to a broad range of commercial spaces, providing the necessary heating and cooling loads efficiently.

The YCZ series incorporates advanced compressor technology, utilizing variable speed compressors that adjust operation based on the actual load requirements. This ensures optimized energy consumption, making it an environmentally responsible choice. Additionally, these compressors minimize noise levels, promoting a quieter indoor environment.

Energy efficiency is a hallmark of the YCZ035F1 and YCZ036F1/3M0B. They feature high-efficiency fans and coils, maximizing airflow while minimizing energy use. These units also boast advanced control systems that enable precise temperature regulation, further driving energy savings. The integration of smart technology allows for remote monitoring and control, enhancing operational efficiency and simplifying maintenance routines.

Durability is paramount in the design of the Trane YCZ series. Constructed with high-quality materials, these units are built to withstand the rigors of outdoor environments. The corrosion-resistant finishes and robust frames contribute to a longer lifespan, reducing the total cost of ownership over time.

The YCZ series also emphasizes indoor air quality, incorporating advanced filtration systems that enhance air cleanliness. This is crucial for commercial spaces where air quality directly impacts occupant health and productivity. Furthermore, the units can be easily integrated with additional ventilation systems, ensuring compliance with stringent air quality standards.

In summary, the Trane YCZ035F1 and YCZ036F1/3M0B are exemplary examples of advanced HVAC technology, offering flexible configurations, superior energy efficiency, durability, and enhanced indoor air quality. Businesses looking for reliable and efficient HVAC solutions will find these rooftop units to be an excellent choice for their commercial applications.