GE JN327, JV367*, JV338*, JV348*, JV347*, RN328 Mark Holes, CUT Holes, RUN Wires

Page 12

Installation Instructions

11MARK HOLES

Select the vent option that your installation will require and proceed to that section:

A. Outside top exhaust

(Vertical duct–314x 10Rectangular)

Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Hood mounting screws (4)

 

 

 

 

 

1334(30hood)

 

 

 

 

 

 

 

1334(30hood)

1634(36hood)

 

 

 

1634(36hood)

 

 

Cabinet front

 

 

 

 

 

 

 

 

 

 

734

 

 

 

Cabinet Bottom

 

 

 

514

514

114

958

334

Vertical duct

 

access hole

 

 

 

12

 

 

138

 

 

 

 

 

Electrical access hole

Wood shims

 

 

 

(in cabinet bottom)

(recessed-bottom cabinetsCenter

 

only–shims must be a

line

 

minimum of 3/8thick

 

 

 

 

and cut to fit the width of the inner recessed cabinet bottom)

B.Outside top exhaust (Vertical duct–7Round)

Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Hood mounting screws (4)

1334(30hood)

 

 

 

13

3

(30

hood)

1634(36hood)

 

4

 

16

3

(36

hood)

 

 

4

 

Cabinet front

Cabinet

 

734

 

 

 

bottom

8DIA.

 

9

5

8

Access

114

HOLE

 

hole for 7

 

534

 

 

 

round duct

 

138

 

 

 

 

 

 

 

 

 

 

 

Wood shims

 

Electrical access

Center

hole (in cabinet bottom)

(recessed-bottom cabinets

line

 

only–shims must be a minimum

 

of 3/8thick and cut to fit the

 

 

width of the inner recessed

 

 

cabinet bottom)

 

 

C. Outside rear exhaust

(Horizontal duct–314x 10Rectangular)

Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Wood shims

(recessed-bottom cabinets only–shims must be a minimum of 3/8thick and cut to fit the width of the inner recessed cabinet bottom)

 

Cabinet front

12114

334

Horizontal duct

 

Cabinet

access hole

 

 

514

514

 

bottom

 

1334(30hood)

 

734

 

 

1334(30hood)

1634(36hood)

 

1634(36hood)

Hood mounting screws (4) Center line

Electrical access hole

(in wall)

 

 

D. Recirculating (non-vented ductless– JN327 and RN328, and optional on JV347, JV348 and JV367 models only)

Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots.

Since the hood is to be recirculated (not to be vented outside), do not cut out any vent openings in the wall or cabinet bottom.

12CUT HOLES

Cut holes at marked locations for duct and electrical wiring. For the vertical duct, cut out 3/4″ extra toward the front of the cabinet so you can move the duct freely when installing the hood. It may also ease installation by cutting the hole 1012″ instead of 10″.

13RUN WIRES

Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes.

NOTE: DO NOT turn the power on until installation is complete.

12

Image 12
Contents Range Hoods Safety Precautions Lisez ET Conservez CES Instructions Using the hood controls Instructions Ductwork Requirements Exhaust connectionMaximum duct length Elbows, transitions, wall and roofcaps, etcInstallation Instructions WORKSHEET-CALCULATE Total Equivalent Ductwork LengthDamage SHIPMENT/INSTALLATION Mounting SpaceTools YOU will Need Parts IncludedChoose Vent Option Remove Wiring Cover Reverse the Baffle for Ducted Installations onlyRemove Wiring Knockout Remove Exhaust AdaptorFor 7″ Round Vertical Ducted Discharge Installations only For RECESSED-BOTTOM Cabinets onlyRUN Wires Mark HolesCUT Holes Optional Power Cord KIT JXHC1 Feed in WiresConnect Ductwork to Hood Ducted installations only Screw in PartwayInstall Light Bulb Follow Electrical Code Connect WiringReplace Wiring Cover Troubleshooting ChecklistGE Range Hood Warranty Consumer Support GE Appliances Website
Related manuals
Manual 16 pages 25.21 Kb