GE JV367*, JN327 Installation Instructions, WORKSHEET-CALCULATE Total Equivalent Ductwork Length

Page 7

Installation Instructions

WORKSHEET—CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH

DUCT

EQUIVALENT NUMBER

 

 

PIECES

LENGTH

x USED

= TOTAL

314x 10

1 Ft.

x

(

)

=

Ft.

Rect.,

 

 

 

 

 

 

straight

 

 

 

 

 

 

7Round,

1 Ft.

x

(

)

=

Ft.

straight

 

 

 

 

 

 

6Round,

1 Ft.

x

(

)

=

Ft.

straight

 

 

 

 

 

 

314x 10

14 Ft.

x

(

)

=

Ft.

Rect. 90°

 

 

 

 

 

 

elbow

 

 

 

 

 

 

314x 10

8 Ft.

x

(

)

=

Ft.

Rect. 45°

 

 

 

 

 

 

elbow

 

 

 

 

 

 

314x 10

33 Ft.

x

(

)

=

Ft.

Rect. 90°

 

 

 

 

 

 

flat elbow

 

 

 

 

 

 

314x 10

24 Ft.

x

(

)

=

Ft.

Rect.

(18 ft. w/o

 

 

 

 

 

wall cap

damper)

x

(

)

=

Ft.

with

 

 

 

 

 

 

damper

 

 

 

 

 

 

314x 10

2 Ft.

x

(

)

=

Ft.

Rect. to

 

 

 

 

 

 

6round

 

 

 

 

 

 

transition

 

 

 

 

 

 

314x 10

4 Ft.

x

(

)

=

Ft.

Rect. to

 

 

 

 

 

 

6round

 

 

 

 

 

 

transition

 

 

 

 

 

 

90° elbow

 

 

 

 

 

 

6Round,

12 Ft.

x

(

)

=

Ft.

90° elbow

 

 

 

 

 

 

6Round,

7 Ft.

x

(

)

=

Ft.

45° elbow

 

 

 

 

 

 

 

Subtotal column 1

 

=

Ft.

MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of a 314″ x 10″ rectangular, 6″ or 7″ diameter round duct should not exceed 65 equivalent feet.

DUCT

EQUIVALENT

 

NUMBER

 

 

PIECES

LENGTH

x USED

= TOTAL

6Round

24 Ft.

x

(

)

=

Ft.

wall cap

(18 ft. w/o

 

 

 

 

 

with

damper)

x

(

)

=

Ft.

damper

 

 

 

 

 

 

6Round

33 Ft.

x

(

)

=

Ft.

roof cap

 

 

 

 

 

 

6Round

2 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

314x 10

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition

 

 

 

 

 

 

6Round

4 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

314x 10

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition

 

 

 

 

 

 

90° elbow

 

 

 

 

 

 

7Round,

14 Ft.

x

(

)

=

Ft.

90° elbow

 

 

 

 

 

 

7Round,

9 Ft.

x

(

)

=

Ft.

45° elbow

 

 

 

 

 

 

7Round

28 Ft.

x

(

)

=

Ft.

wall cap

(21 ft. w/o

 

 

 

 

 

with

damper)

x

(

)

=

Ft.

damper

 

 

 

 

 

 

7Round

39 Ft.

x

(

)

=

Ft.

roof cap

 

 

 

 

 

 

7Round

1 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

314x 10

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition

 

 

 

 

 

 

7Round

5 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

314x 10

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition,

 

 

 

 

 

 

90° elbow

 

 

 

 

 

 

 

Subtotal column 2

 

=

Ft.

 

Subtotal column 1

 

=

Ft.

Total ductwork

=

Ft.

7

Image 7
Contents Range Hoods Safety Precautions Lisez ET Conservez CES Instructions Using the hood controls Instructions Elbows, transitions, wall and roofcaps, etc Ductwork RequirementsExhaust connection Maximum duct lengthWORKSHEET-CALCULATE Total Equivalent Ductwork Length Installation InstructionsParts Included Damage SHIPMENT/INSTALLATIONMounting Space Tools YOU will NeedChoose Vent Option Remove Exhaust Adaptor Remove Wiring CoverReverse the Baffle for Ducted Installations only Remove Wiring KnockoutFor RECESSED-BOTTOM Cabinets only For 7″ Round Vertical Ducted Discharge Installations onlyMark Holes RUN WiresCUT Holes Screw in Partway Optional Power Cord KIT JXHC1Feed in Wires Connect Ductwork to Hood Ducted installations onlyTroubleshooting Checklist Install Light Bulb Follow Electrical CodeConnect Wiring Replace Wiring CoverGE Range Hood Warranty Consumer Support GE Appliances Website