Installation Instructions
[] SECURE HOOD
Slide the hood back against the wall. Tighten
the mounting screws. Be sure the screw heads are in the narrow neck of the keyhole slot.
[] CONNECT WIRING
Connect house black to hood black wire, house
white to hood white wire, and house grotmd trader
green ground screw. Securely tighten the strain relief clamp onto the house wiring.
ir0und screw
(4)
Keyhole(4)
NOTE: DO NOT PUSH ON E__N BI,ADE. Pushiw,
on the blade ma_ cause it to interiere with other
hood parts.
[] CONNECT DUCTWORK TO
HOOD
Use duct tape to make joints secm'e and air tight.
Ducttape
[] INSTALL LIGHT BULBS
Pro'chase and install two PAR20, 50 _\ maximum
halogen bulbs.
[] REPLACE WIRING COVER
On models so equipped, replace the wiring coxer or the bottolU coxer.
[] REPLACE FILTERS
Make sm'e tan blade turns freel). The installation is complete. Turn on power at set\ice panel, and test
fi)r proper operation.
[] FOLLOW ELECTRICAL CODE
Complete the electrical wiring according to
National Electrical Code and local codes.
NOTE: This hood must be pemmnently grotmded.
Connect house wMng (120 VAC) to hood wiring.
TROUBLESHOOTING CHECKLIST
]f the hood seems to be operating at high speed when the control is not set on high, or if ventilation seems
inadequate, check the ti_llowing:
U_JKnockouts not removed from hood.
Damper blade not opening.
Reduced airflow because the duct is too small or the duct length is too long.
The duct is blocked.
U_JUndersized or restrictive wall or roof cap.
14