GE JVB37, JVB67 owner manual Install Downdraft Vent, Install the Ductwork

Page 15

Install Downdraft Vent

Optional method

Secure to cabinet side with top screw on case

Or use second screw

Preferred method

Secure the upper brackets with screws located on the side of case and attach to back of cabinet

Secure the lower brackets

to blower housing

Safety Instructions Operating Instructions Installation

Place the downdraft vent into the countertop cutout, against the back side.

Secure the downdraft to the countertop supplied brackets. See illustration.

Fasten brackets to top screws on the front side of the vent, secure to cabinet side wall just below the countertop. Or,

Fasten one bracket to vent side and secure to cabinet back wall.

Install two brackets on the bottom of the vent. Attach brackets to slide screws on the vent and to the floor using wood screws (not supplied).

When installing in a tile countertop surface, it may be necessary to apply a locally approved caulking to cover any gaps.

Instructions

Install the Ductwork

Use minimum 26gauge galvanized or 24 gauge aluminum duct 314 x 10or 6round. PVC duct should be used if installing under a poured concrete slab.

DO NOT USE flexible ducting.

Always use appropriate roof or wall cap with damper. Laundry type wall caps should never be used.

Use the straightest duct run possible.

For satisfactory performance the duct run should not exceed 150 ft. or its equivalent length when bends or various fittings are used. Refer to the table of equivalent lengths to calculate your installation.

Duct tape over

seam and screw

Air

Flow

Screw

Install ductwork so the piece of duct nearest the downdraft unit slots INTO the next piece of the duct. Secure the joints with self-tapping screws and apply duct tape around the joints to ensure an airtight seal.

Troubleshooting Tips Consumer Support

15

Image 15
Contents Write the model and serial numbers here Model # Serial # 959-0278-001 Rev. BElectric SHOCK, or Injury to Persons Observe the Following Safety Precautions Read and Save These Instructions Using the Cooktop Using the downdraft systemSafety Instructions Troubleshooting Tips Consumer SupportPainted or metal surfaces Consumer SupportCooking Tips Grease filtersImportant Save these instructions for the local To PERSONS, Observe the FollowingIf cabinetry is used above the cooking surface InstructionsAdvance Planning-Ductwork 30″ Cooktops/Downdraft Unit JVB37 36″ Cooktops/Downdraft Unit JVB67 Cutting guide Gas Cooktops Power SupplyOperating Ductwork Length and Dust FittingsDischarge direction Side to side adjustmentsVenting Options RotationInstall the Ductwork Install Downdraft VentInstall Raise/Lower Switch Operating Instructions Connect PowerInstalling the Cooktop Safety InstructionsVent does not rise Before You Call For Service…RAISE/LOWER switch did Fan does not workOne Year GE Downdraft System WarrantyFor The Period GE Will Replace What GE Will Not CoverReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website
Related manuals
Manual 40 pages 9.53 Kb Manual 20 pages 37.21 Kb

JVB37, JVB67 specifications

The GE JVB37 and JVB67 are advanced connected commercial water heaters designed to meet the challenges of modern facilities while prioritizing efficiency, safety, and reliability. With an acute emphasis on smart technology, these models provide user-friendly features and robust performance for various applications, including restaurants, hotels, and multi-family buildings.

One of the standout features of the GE JVB37 and JVB67 is their energy efficiency. Both models utilize a state-of-the-art heat pump technology, which allows them to consume significantly less energy compared to traditional electric or gas-fired water heaters. This results in lower operating costs and a reduced environmental footprint, making them ideal choices for businesses looking to enhance their sustainability efforts.

The JVB37 has a 37-gallon capacity, while the JVB67 offers a larger 67-gallon capacity, catering to different usage requirements. These models are equipped with an intuitive digital interface that provides real-time monitoring and control, ensuring users can easily adjust the temperature settings and monitor energy consumption. Moreover, the connectivity features enable remote management through mobile apps or smart devices, providing added convenience for facility managers.

In terms of safety, both models incorporate advanced features such as leak detection, automatic shut-off valves, and tamper-proof designs. These safeguards help prevent potential hazards while ensuring a reliable supply of hot water. Furthermore, the build quality of the JVB37 and JVB67 reflects GE's commitment to longevity, with durable materials that resist corrosion and wear, ensuring years of dependable service.

The installation of the JVB37 and JVB67 is simplified due to their compact designs, allowing for flexibility in various settings. Whether mounted on the wall or positioned in tight spaces, these water heaters can adapt to different layouts without compromising performance.

Overall, the GE JVB37 and JVB67 are exemplary models in the market of connected commercial water heaters, seamlessly blending innovation with practicality. Their energy-efficient operation, combined with smart technologies and robust safety features, makes them ideal solutions for businesses aiming to optimize their hot water needs while prioritizing sustainability and efficiency.