GE JVB67, JVB37 owner manual Instructions, If cabinetry is used above the cooking surface

Page 8

Instructions

Installation of the downdraft system. Read these instructions completely and carefully.

IMPORTANT: These vents are recommended for island installations. Against-the-wall installations are limited due to countertop depth requirements. The vent and cooktop combined depth requires an extra deep flat countertop surface.

Instructions Safety

The countertop must be at least 26″ deep with a flat surface area of 2312″ or more, front to back (NOTE: JGP932S requires 2334″ flat surface area and JP350SC, JP930SC and JP938SC require 2358″ flat surface area).

In addition, other clearances to the front edge of the countertop must be considered.

–See specific cutout illustrations with your cooktop model to determine requirements.

–A countertop with a raised lip or rolled front edge may not allow enough flat area for installation.

Flat surface area

24

Tips Installation Instructions Operating

Installation Possibilities

When the kitchen design calls for an against the wall

In an island or peninsula, the countertop can be extra

installation, move 24″ deep base cabinet forward,

deep to provide seating opposite of the cooktop.

3″ to 5″. Filler panels can be angled or flat to fill the

Adding base cabinets on each side of the cooktop

space between adjacent cabinets.

provides extra storage and countertop work space.

Maintain cutout clearances to front edge as specified

 

 

 

 

B18

 

 

 

Base to sink

 

 

 

BS30 to BS42

Countertop

 

 

 

overhang per

 

 

B18

cooktop

 

 

 

clearances must

 

Filler panel

 

be maintained

 

 

 

Filler panel

Base sink

 

End panel

BS30 Min. for JVB37

Cover panel

Base cabinet

BS36 Min. for JVB67

 

Advance Planning—Clearances

Consumer Support Troubleshooting

Installation must conform with local codes.

The downdraft system with blower, motor and duct work will occupy the cabinet below the countertop and cooktop.

The blower/motor assembly can be located below the cabinet floor. The assembly will fit between 16″ floor joists.

–In this installation a transition to 6 round is required.

The blower motor assembly can also be installed outdoors. Order JXBC57 for remote blower installations outdoors.

Refer to “Cooktop Clearances” for information on appropriate placement and necessary clearances when planning installation.

Refer to your specific cooktop installation instruction for other appropriate clearances.

Avoid placing cabinetry directly above the

8cooking surface when possible.

If cabinetry is used above the cooking surface:

–Installation must conform with local codes. –Use cabinets no more than 13″ deep.

–Maintain 30″ minimum clearance between cooktop and unprotected cabinets directly above cooktop.

–If clearance is less than 30″, protect cabinet bottoms with flame-retardant millboard at least 1/4″ thick or gypsum board at least 3/16″ thick covered with 28 gauge sheet steel or .02″ thick copper.

–Clearance between cooktop and protected cabinetry must not be less than 24.″

EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.

Working areas adjacent to the cooktop should maintain 18″ minimum clearance between countertop and cabinet bottom.

Image 8
Contents 959-0278-001 Rev. B Write the model and serial numbers here Model # Serial #Electric SHOCK, or Injury to Persons Observe the Following Safety Precautions Read and Save These Instructions Using the downdraft system SafetyInstructions Troubleshooting Tips Consumer Support Using the CooktopConsumer Support Cooking TipsGrease filters Painted or metal surfacesTo PERSONS, Observe the Following Important Save these instructions for the localInstructions If cabinetry is used above the cooking surfaceAdvance Planning-Ductwork 30″ Cooktops/Downdraft Unit JVB37 36″ Cooktops/Downdraft Unit JVB67 Cutting guide Power Supply OperatingDuctwork Length and Dust Fittings Gas CooktopsSide to side adjustments Venting OptionsRotation Discharge directionInstall Downdraft Vent Install the DuctworkInstall Raise/Lower Switch Connect Power Installing the CooktopSafety Instructions Operating InstructionsBefore You Call For Service… RAISE/LOWER switch didFan does not work Vent does not riseGE Downdraft System Warranty For The Period GE Will ReplaceWhat GE Will Not Cover One YearSchedule Service Parts and AccessoriesConsumer Support GE Appliances Website Real Life Design Studio
Related manuals
Manual 40 pages 9.53 Kb Manual 20 pages 37.21 Kb

JVB37, JVB67 specifications

The GE JVB37 and JVB67 are advanced connected commercial water heaters designed to meet the challenges of modern facilities while prioritizing efficiency, safety, and reliability. With an acute emphasis on smart technology, these models provide user-friendly features and robust performance for various applications, including restaurants, hotels, and multi-family buildings.

One of the standout features of the GE JVB37 and JVB67 is their energy efficiency. Both models utilize a state-of-the-art heat pump technology, which allows them to consume significantly less energy compared to traditional electric or gas-fired water heaters. This results in lower operating costs and a reduced environmental footprint, making them ideal choices for businesses looking to enhance their sustainability efforts.

The JVB37 has a 37-gallon capacity, while the JVB67 offers a larger 67-gallon capacity, catering to different usage requirements. These models are equipped with an intuitive digital interface that provides real-time monitoring and control, ensuring users can easily adjust the temperature settings and monitor energy consumption. Moreover, the connectivity features enable remote management through mobile apps or smart devices, providing added convenience for facility managers.

In terms of safety, both models incorporate advanced features such as leak detection, automatic shut-off valves, and tamper-proof designs. These safeguards help prevent potential hazards while ensuring a reliable supply of hot water. Furthermore, the build quality of the JVB37 and JVB67 reflects GE's commitment to longevity, with durable materials that resist corrosion and wear, ensuring years of dependable service.

The installation of the JVB37 and JVB67 is simplified due to their compact designs, allowing for flexibility in various settings. Whether mounted on the wall or positioned in tight spaces, these water heaters can adapt to different layouts without compromising performance.

Overall, the GE JVB37 and JVB67 are exemplary models in the market of connected commercial water heaters, seamlessly blending innovation with practicality. Their energy-efficient operation, combined with smart technologies and robust safety features, makes them ideal solutions for businesses aiming to optimize their hot water needs while prioritizing sustainability and efficiency.