GE FGB-M05 Production-modes, Continue, Weight-Alarm, Weight-Error, Mixer-mode, Normal, Pulsing

Page 8

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 7

 

Gravimetric Blender

 

2.4Production-modes

The production-mode of the blender indicates how the production will stop in automatic- mode. This parameter can be changed using the menu (F1) ‘controller / public parameters’. The production-mode has three options:

Continue

The blender will not stop automatically after the start-command. The blender will continue the production, unless the blender runs out of material or an error occurs.

Weight->Alarm

If ‘Weight->Alarm’ has been chosen, a requested weight has to be given. After a start the requested weight will be compared with ‘produced-weight’. If both are the same or the

‘produced-weight’ higher, the controller will send an alarm to the operator-interface. The production will continue.

The alarm can be recovered setting the ‘production-weight’ to zero (0). This command is part of the option-menu (F2) of the status screen.

Weight->Error

When using the option ‘Weight->Error’ a weight has to be given. After a start the requested

weight will be compared with ‘production-weight’. If both are the same or the

‘production-weight’ higher, the controller will send an error to the operator-interface. The production will not continue in this case.

2.5Mixer-mode

When all components are dispensed, the contents of the weighbin will be emptied. The mixer in the mixing chamber, which contains the dispensed components, can be put in different modes. Choose the menu (F1) ‘controller/public parameters’.

Normal

The mixer is off during production. If the components are dumped from the weighbin into the mixer chamber the mixer will be on for a predefined number of seconds, defined by ‘mixerOnTime’. This parameter can only be changed if this option is chosen.

Pulsing

The mixer will pulse during production. Both on- and off-time ca be defined using the parameters mixerPulseOnTime (time on) and mixerPulseOffTime (time off). These parameters can only be changed if this option is chosen.

Off

The mixer is always off.

On

The mixer is always on, when the machine status is active.

Image 8
Contents Manual Serial No ISO 08.01.02.064.GB 986731 Rev. MayIntroduction Controls Installation Introduction Gravimetric Feeding Features are Options areBlender start-up Blender statusInactive StandbyError PauseStop requested Machine-modeWeight-Alarm Weight-ErrorProduction-modes ContinueVolumetric Dispense modesGravimetric CombinationRecipe to weight calculation Method StandardExample TotalMethod Percentage Adding extra materialsAdditive to regrind Additive to RegrindRegrind control Empty regrind ControlStock Silo Control Dispense not correct too little DispensingDispense is correct Dispense not correct too much Condition 1. The mixbin-vale may not be open if presentCondition 2. The mixerchamber may not be full CalculationsDatalogging EQ-Net Certificate ISO Certificat Operator-interface Keyboard Function KEY in MACHINE-MODEKey Description User control ButtonNumber input field Text input field0OPERATING Auto Status Operating Mode AutomaticChange components Example Add a new component Actions?WHITE? Natural White Natural ?White Natural Regrind Additive White ?ADDITIVE ?2 Add/change recipes Example Add a new recipe Field of a RecipeOption Menu in EDIT-RECIPE Step ‘edit recipes’ Enter StandardPercentage Additive WhiteChange current recipe Timely information Production screenMaterial usage screen Crates YellowAdjustment of the gravimetric blender Input & Output monitorCalibration of the weigh bin Tare of the weighbinStandard adjustment Hardware-reactiontimeOverview of parameters Public parametersParameter Description Init ContinueGravimetric PulseProtected parameters Protected Parameters Reports and overviews Change entrycodeMenu hierarchy Change date and timeRevision code of the system System ProductionController Services MountingRev. May GraviMaster-FGB-M05 S Gravimetric Blender Alarms Alarm reports and solutions Alarm-message Description Action to cancel alarm Rev. May GraviMaster-FGB-M05 S Gravimetric Blender Status Operating Maintenance Adjusting sensor sensitivityTransportation of the GraviMaster Replacement of parts Replacement of printed circuitCleaning the machine Safety measures General machine specificationsUser-interface specifications Valves specificationsEin Electrical diagrams Rev. May GraviMaster-FGB-M05 S Gravimetric Blender Rev. May GraviMaster-FGB-M05 S Gravimetric Blender

FGB-M05 specifications

The GE FGB-M05 is a cutting-edge gas turbine designed for a variety of industrial applications, showcasing remarkable efficiency and advanced technology. As a part of General Electric's extensive portfolio of power generation solutions, the FGB-M05 stands out for its versatility and reliability.

One of the main features of the FGB-M05 is its modular design, which allows for easy maintenance and adaptability to different operating conditions. This modularity helps reduce downtime and enhances overall operational efficiency. The gas turbine is engineered to optimize performance across a wide range of workloads, making it suitable for both base load and peak shaving applications.

Incorporating advanced aerodynamics, the FGB-M05 leverages high-efficiency compressor stages that significantly improve its operational performance. The turbine features state-of-the-art cooling technologies that enhance combustion efficiency while ensuring longer equipment life. This is particularly important in high-temperature applications, where maintaining material integrity is crucial.

The FGB-M05 is equipped with sophisticated control systems that enable real-time monitoring and optimization of its operational parameters. These control systems enhance the turbine’s capability to respond dynamically to changing load demands, ensuring that it operates at peak efficiency at all times. Additionally, the turbine supports a range of fuels, including natural gas and biogas, making it a versatile choice for various power generation needs.

Furthermore, the FGB-M05 incorporates advanced emissions control technologies, reducing its environmental impact. It is designed to meet stringent emissions regulations, boasting low NOx and CO emissions levels, which are essential for compliance in many regions.

The GE FGB-M05 gas turbine is also noted for its compact footprint, making it an ideal solution for locations where space is limited. Its combination of high performance, flexibility, and reduced emissions makes it a preferred choice for energy providers looking to invest in sustainable and efficient power generation technologies.

In summary, the GE FGB-M05 gas turbine stands as a testament to modern engineering, combining innovative features, robust technology, and a commitment to environmental responsibility. Whether for industrial applications, peaking plants, or renewable integration, the FGB-M05 delivers reliability and excellence in performance.