GE FGB-M05 Hardware-reactiontime, Standard adjustment, Overview of parameters, Public parameters

Page 33

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 32

 

Gravimetric Blender

 

3.4.3Hardware-reactiontime

The adjustment of the number of pulses is very important for the autopulse system of the FGB-M05. When dosing less than 8 gram of material, the GraviMaster will switch over to the autopulse system. In the hardware-reactiontime the opening time can be adjusted by increasing the clockpulses. One clockpulse is 5 ms (0,005 s).

The autopulse system does not caculate the rate in g/s but in g/puls. It calculates how many pulses he needs for an amount of material. This is why it is very important that the opening time of the pulse is not too long, because it cannot dose accurate anymore.

Standard adjustment:

Hopper

Clockpulses

Time (s)

 

 

 

1

3

0,015

 

 

 

2

4

0,020

3

4

0,020

 

 

 

4

3

0,015

 

 

 

3.5Overview of parameters

The controller has a great number of parameters. The parameters are necessary to control the machine with all its features. The parameters are broken down into two groups; public- parameters and protected-parameters. Free parameters may be changed by an operator, protected parameters may only be changed if the password is given.

3.5.1Public parameters

Below a list is given of all parameters which are attainable by the menu (F1) ‘controller / public parameters’.

Image 33
Contents Serial No ISO 08.01.02.064.GB 986731 Rev. May ManualIntroduction Controls Installation Introduction Gravimetric Feeding Options are Features areBlender status Blender start-upInactive StandbyPause ErrorStop requested Machine-modeWeight-Error Weight-AlarmProduction-modes ContinueDispense modes VolumetricGravimetric CombinationMethod Standard Recipe to weight calculationExample TotalAdding extra materials Method PercentageAdditive to Regrind Additive to regrindRegrind control Empty regrind ControlStock Silo Control Dispensing Dispense is correctDispense not correct too little Condition 1. The mixbin-vale may not be open if present Dispense not correct too muchCondition 2. The mixerchamber may not be full CalculationsDatalogging EQ-Net Certificate ISO Certificat Function KEY in MACHINE-MODE Operator-interface KeyboardKey Description Button User controlNumber input field Text input fieldStatus Operating Mode Automatic Change components0OPERATING Auto Actions Example Add a new componentWhite Natural ? ?WHITE? NaturalWhite Natural Regrind Additive White ?ADDITIVE ?2 Add/change recipes Field of a Recipe Option Menu in EDIT-RECIPEExample Add a new recipe Standard Step ‘edit recipes’ EnterAdditive White PercentageChange current recipe Production screen Timely informationCrates Yellow Material usage screenInput & Output monitor Adjustment of the gravimetric blenderCalibration of the weigh bin Tare of the weighbinHardware-reactiontime Standard adjustmentOverview of parameters Public parametersContinue Parameter Description InitGravimetric PulseProtected parameters Protected Parameters Change entrycode Reports and overviewsChange date and time Revision code of the systemMenu hierarchy Production ControllerSystem Mounting ServicesRev. May GraviMaster-FGB-M05 S Gravimetric Blender Alarms Alarm reports and solutions Alarm-message Description Action to cancel alarm Rev. May GraviMaster-FGB-M05 S Gravimetric Blender Status Operating Adjusting sensor sensitivity MaintenanceReplacement of parts Replacement of printed circuit Cleaning the machineTransportation of the GraviMaster General machine specifications Safety measuresUser-interface specifications Valves specificationsEin Electrical diagrams Rev. May GraviMaster-FGB-M05 S Gravimetric Blender Rev. May GraviMaster-FGB-M05 S Gravimetric Blender

FGB-M05 specifications

The GE FGB-M05 is a cutting-edge gas turbine designed for a variety of industrial applications, showcasing remarkable efficiency and advanced technology. As a part of General Electric's extensive portfolio of power generation solutions, the FGB-M05 stands out for its versatility and reliability.

One of the main features of the FGB-M05 is its modular design, which allows for easy maintenance and adaptability to different operating conditions. This modularity helps reduce downtime and enhances overall operational efficiency. The gas turbine is engineered to optimize performance across a wide range of workloads, making it suitable for both base load and peak shaving applications.

Incorporating advanced aerodynamics, the FGB-M05 leverages high-efficiency compressor stages that significantly improve its operational performance. The turbine features state-of-the-art cooling technologies that enhance combustion efficiency while ensuring longer equipment life. This is particularly important in high-temperature applications, where maintaining material integrity is crucial.

The FGB-M05 is equipped with sophisticated control systems that enable real-time monitoring and optimization of its operational parameters. These control systems enhance the turbine’s capability to respond dynamically to changing load demands, ensuring that it operates at peak efficiency at all times. Additionally, the turbine supports a range of fuels, including natural gas and biogas, making it a versatile choice for various power generation needs.

Furthermore, the FGB-M05 incorporates advanced emissions control technologies, reducing its environmental impact. It is designed to meet stringent emissions regulations, boasting low NOx and CO emissions levels, which are essential for compliance in many regions.

The GE FGB-M05 gas turbine is also noted for its compact footprint, making it an ideal solution for locations where space is limited. Its combination of high performance, flexibility, and reduced emissions makes it a preferred choice for energy providers looking to invest in sustainable and efficient power generation technologies.

In summary, the GE FGB-M05 gas turbine stands as a testament to modern engineering, combining innovative features, robust technology, and a commitment to environmental responsibility. Whether for industrial applications, peaking plants, or renewable integration, the FGB-M05 delivers reliability and excellence in performance.