GE SCB 1001, ZSC 1001, ZSC 1000 manual Upper Heater Assembly, To remove the upper heater assembly

Page 34

Upper Heater Assembly

The halogen heater has an approximate resistance value of 1.8 to 3.7 . It is connected using a white wire harness.

The ceramic heater has an approximate resistance value of 15 to 25 . It is connected using a yellow wire harness.

To remove the upper heater assembly:

Caution: Mark each of the wire harnesses before disconnecting. The connectors could be interchanged, causing an adverse effect in cooking performance.

1.Remove the oven from cabinet or wall opening and remove the outer cover. (See Oven Removal / Partial Removal.)

2.Disconnect the heater assembly wire harnesses and pull them through the wire guide.

3.Disconnect wires from the upper heater TCO.

4.Remove the 2 Phillips-head screws, wire retainer, and the heater shield from the heater assembly.

5.Straighten the 4 folded lock tabs.

6.Remove the 8 Phillips-head screws that attach the heater cover. Lift off the cover.

Lock Tabs

7.Remove the 3 Phillips-head screws that attach the heater assembly to the oven chassis.

8.Carefully lift the heater assembly from the oven chassis.

– 34 –

Image 34
Contents Technical Service Guide Important Safety Notice Page Table of Contents Model Number NomenclatureB 1 0 0 0 D B B Serial NumberFeatures and Benefits IntroductionUpper Halogen Lamp/Ceramic Heater Control Features SPEEDCOOK/Repeat LastCooking Times Rear Convection Heat Element Speed Cook SystemHalogen Lamp and Ceramic Heaters MicrowaveLower Heater Speedcook Power LevelsUpper Heaters Microwave EnergyThermal Protection Voltage Compensation ChartThermal Compensation Chart Initial Cavity Thermal CompensationSpeedcook Power Level Chart Upper HeaterAdvance Planning InstallationSingle Advantium 120 Installation Electrical RequirementsFront View Component Locator ViewsMain Component Locator View Top View Bottom ViewLeft Side View Right Side ViewControl Panel Assembly Shown separated Power Board Control Boards and Panel ConnectionsRelay Board Control BoardSelector Board Display BoardControl Panel Component Access Chart ComponentsOven Removal / Partial Removal Access CoverOuter Cover Door Removal Door AssemblyDoor-Removal Position To disassemble the doorControl Panel Assembly To remove the control panel assemblyTo remove the power board To remove the relay boardTo remove the control board To remove the control panel bracketTo remove the display board To remove the control panel Low Voltage TransformerTo remove the selector board Resistance CheckCavity Light Fuse Noise Filter Capacitor and DiodeHigh Voltage Transformer Magnetron and Magnetron TCOMagnetron TCO Damper Assembly Blower AssemblyUpper Heater and Oven Cavity TCOs Upper Heater Assembly To remove the upper heater assemblyTo remove the lower heater assembly Lower Heater AssemblyConvection Heater Assembly and Thermistor ThermistorConvection Heater Element Convection Fan MotorHumidity Sensor Turntable Motor Humidity Sensor TestHow to Test the Monitor Switch Left and Right Door Switch AssembliesHow to Test Primary Interlock and Door Sensing Switches How to Test Interlock SystemHow to Adjust the Interlocks Rotate SwitchTo replace the door switches To replace the latch boards Diagnostics and Service Information Standard Test Load Demo ModeFault Codes Display Failure DetectedProof Feature Microwave Leak TestSchematics and Wiring Diagrams PCB Warranty For The Period GE Will Replace

SCB 1000, SCB 1001, ZSC 1000, ZSC 1001 specifications

The GE ZSC 1001, ZSC 1000, SCB 1001, and SCB 1000 are cutting-edge solutions in the realm of electrical substations, designed to enhance efficiency, reliability, and safety in power management systems. These devices are integral for utilities seeking to modernize their infrastructures while maintaining optimal performance.

The GE ZSC 1000 series includes both the ZSC 1000 and ZSC 1001 models. These digital relays are renowned for their sophisticated protection and control capabilities. One of the standout features of the ZSC 1001 is its enhanced communication technology, enabling seamless integration with various systems and allowing for real-time data exchange. This model offers advanced protection functions, including overcurrent, distance, and differential protection, which are essential for safeguarding electrical assets.

The ZSC 1000 series is built on a modular architecture, facilitating easy upgrades and customization to meet specific operational needs. It employs intelligent data analysis to help operators predict equipment failures before they happen, ultimately minimizing downtime and maintenance costs. Additionally, the devices boast user-friendly interfaces that simplify monitoring and control tasks.

The SCB 1000 and SCB 1001 are also key players in GE's portfolio, tailored for busbar protection and automation. These models feature high-accuracy current sensing technology and extensive programmable parameters to suit diverse applications. Their design allows for robust performance in harsh environments, making them ideal for substations.

Both SCB models utilize advanced digital signal processing (DSP) technologies, which enhance their performance and improve the reliability of measurements. The SCB 1001 takes a step further by incorporating security measures to protect against cyber threats, ensuring the integrity of data within the grid.

In terms of interoperability, all four models support various communication protocols, facilitating better connectivity and integration with existing infrastructure. They are designed to operate seamlessly in conjunction with SCADA systems, enabling comprehensive monitoring and control functions.

To summarize, the GE ZSC 1001, ZSC 1000, SCB 1001, and SCB 1000 exemplify modern innovations in electrical protection and control. They offer a blend of advanced technologies, modular designs, and robust performance characteristics, making them invaluable assets for any utility looking to enhance its power management systems. These devices not only meet the current demands of the energy sector but are also equipped to adapt to future challenges in the evolving landscape of electrical distribution and management.