GE ZSC 1000, ZSC 1001, SCB 1001, SCB 1000 manual Pcb

Page 45

 

 

 

 

 

RY2

MGT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L-H RY9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY8

U-H(C)

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

RY7

CONV

 

 

 

 

 

 

 

 

 

 

RY11

1

 

 

 

 

PCB

 

 

 

-UH(H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN2

 

MAIN

 

 

 

 

 

 

 

 

7

 

 

1 C11

3

1

 

 

 

 

CN1

 

 

 

 

 

 

 

 

 

BK

 

W

 

 

R

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

CN11

 

 

 

 

CN7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

POWERPCB

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

CN8

13 THERMISTOR

 

 

 

 

 

 

CN5

 

SENSOR

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN6

DOOR

 

 

 

 

 

 

 

 

 

3

 

 

W3

W2

W6

R4 YL3

BL2

W9

YL1

BN3 W4

R7

BK6

W4

BL3

PK1

BN3

GN1

R6

LVT

W

BK

YLBK W

R

BN

HUMIDITY

SENSOR

THERMISTOR

SECONDARY

SENSING S/W

W8

YL4

PK2

BK5

D.MOTOR SENSING S/W

BK2

R1

YL4

W8

BK1

R1

BL2

YL2

BL5

BL5

R7

BN3

R5

BK3

BN4

BL3

W2

YL3

W1

R3

YL2

W5

BK1

BK6

R2

BN1

OVEN TCO

DOOR SENSING

SWITCH

HTR TCO

BK9

UPPER HEATER

(CERAMIC)

R10

W9

UPPER HEATER

(HALOGEN)

W10

BLOWER

MOTOR

OVEN

LAMP

MGT

TCO

MONITOR

SWITCHCONVECTION SHEATH

HEATER

PRIMARY

INTERLOCK

SWITCH CONVECTION

MOTOR

W

YL

R

BL

 

 

 

D.MOTOR

 

 

 

 

 

 

DAMPER

 

 

 

 

 

 

SENSING

 

 

 

 

 

 

MOTOR

SWITCH

1

 

 

 

 

4

 

 

 

GN1

R5

BN2 BN2

BK4

YL1

BK4

BN1 R6

BK5

PK2

GROUND

HARNESS LEADS

PARTS LEADS

COLOR

SYMBOL

RED

R

WHITE

W

BLACK

BK

BROWN

BN

BLUE

BL

GREEN

GN

YELLOW

YL

PINK

P

 

 

GROUND

HARNESS LEADS

PARTS LEADS

CROUND

H.V. DIODE

HVC

MGT TUBE W

R

FA F

5

2

 

1

 

 

 

 

 

W3

W5

4

3

 

 

 

 

 

R2

R3

 

 

 

 

 

BK2 BN4

GN

W1

 

BL1

R4

BL1

BK3

PK1

 

 

 

NOISE

1

 

 

 

 

4

 

 

 

FILTER

 

 

 

 

 

 

 

BK

GN

W

 

BL

R

BL

BK

YL

MOTOR

 

 

 

 

 

 

 

 

 

TURNTABLE

 

P/CORD

 

 

 

 

 

 

LOWER CERAMIC

 

 

 

 

 

 

 

 

 

HEATER

– 45 –

Image 45
Contents Technical Service Guide Important Safety Notice Page Table of Contents B 1 0 0 0 D B B NomenclatureModel Number Serial NumberIntroduction Features and BenefitsUpper Halogen Lamp/Ceramic Heater SPEEDCOOK/Repeat Last Control FeaturesCooking Times Halogen Lamp and Ceramic Heaters Speed Cook SystemRear Convection Heat Element MicrowaveUpper Heaters Speedcook Power LevelsLower Heater Microwave EnergyThermal Compensation Chart Initial Cavity Voltage Compensation ChartThermal Protection Thermal CompensationUpper Heater Speedcook Power Level ChartSingle Advantium 120 Installation InstallationAdvance Planning Electrical RequirementsComponent Locator Views Front ViewMain Component Locator View Bottom View Top ViewRight Side View Left Side ViewControl Panel Assembly Shown separated Control Boards and Panel Connections Power BoardControl Board Relay BoardDisplay Board Selector BoardControl Panel Components Component Access ChartAccess Cover Oven Removal / Partial RemovalOuter Cover Door-Removal Position Door AssemblyDoor Removal To disassemble the doorTo remove the control panel assembly Control Panel AssemblyTo remove the relay board To remove the power boardTo remove the control panel bracket To remove the control boardTo remove the display board To remove the selector board Low Voltage TransformerTo remove the control panel Resistance CheckCavity Light Fuse Capacitor and Diode Noise FilterMagnetron and Magnetron TCO High Voltage TransformerMagnetron TCO Blower Assembly Damper AssemblyUpper Heater and Oven Cavity TCOs To remove the upper heater assembly Upper Heater AssemblyConvection Heater Assembly and Thermistor Lower Heater AssemblyTo remove the lower heater assembly ThermistorConvection Fan Motor Convection Heater ElementHumidity Sensor Test Humidity Sensor Turntable MotorHow to Test Primary Interlock and Door Sensing Switches Left and Right Door Switch AssembliesHow to Test the Monitor Switch How to Test Interlock SystemRotate Switch How to Adjust the InterlocksTo replace the door switches To replace the latch boards Diagnostics and Service Information Fault Codes Demo ModeStandard Test Load Display Failure DetectedMicrowave Leak Test Proof FeatureSchematics and Wiring Diagrams PCB For The Period GE Will Replace Warranty

SCB 1000, SCB 1001, ZSC 1000, ZSC 1001 specifications

The GE ZSC 1001, ZSC 1000, SCB 1001, and SCB 1000 are cutting-edge solutions in the realm of electrical substations, designed to enhance efficiency, reliability, and safety in power management systems. These devices are integral for utilities seeking to modernize their infrastructures while maintaining optimal performance.

The GE ZSC 1000 series includes both the ZSC 1000 and ZSC 1001 models. These digital relays are renowned for their sophisticated protection and control capabilities. One of the standout features of the ZSC 1001 is its enhanced communication technology, enabling seamless integration with various systems and allowing for real-time data exchange. This model offers advanced protection functions, including overcurrent, distance, and differential protection, which are essential for safeguarding electrical assets.

The ZSC 1000 series is built on a modular architecture, facilitating easy upgrades and customization to meet specific operational needs. It employs intelligent data analysis to help operators predict equipment failures before they happen, ultimately minimizing downtime and maintenance costs. Additionally, the devices boast user-friendly interfaces that simplify monitoring and control tasks.

The SCB 1000 and SCB 1001 are also key players in GE's portfolio, tailored for busbar protection and automation. These models feature high-accuracy current sensing technology and extensive programmable parameters to suit diverse applications. Their design allows for robust performance in harsh environments, making them ideal for substations.

Both SCB models utilize advanced digital signal processing (DSP) technologies, which enhance their performance and improve the reliability of measurements. The SCB 1001 takes a step further by incorporating security measures to protect against cyber threats, ensuring the integrity of data within the grid.

In terms of interoperability, all four models support various communication protocols, facilitating better connectivity and integration with existing infrastructure. They are designed to operate seamlessly in conjunction with SCADA systems, enabling comprehensive monitoring and control functions.

To summarize, the GE ZSC 1001, ZSC 1000, SCB 1001, and SCB 1000 exemplify modern innovations in electrical protection and control. They offer a blend of advanced technologies, modular designs, and robust performance characteristics, making them invaluable assets for any utility looking to enhance its power management systems. These devices not only meet the current demands of the energy sector but are also equipped to adapt to future challenges in the evolving landscape of electrical distribution and management.