York BP 090 Installation Safety Information, Preceding Installation, Unit Shipping Bracket

Models: BP120 BP 090

1 44
Download 44 pages 45.17 Kb
Page 8
Image 8
INSTALLATION

66307-YIM-B-0606

INSTALLATION

INSTALLATION SAFETY INFORMATION

Read these instructions before continuing this appliance installation. This is an outdoor combination heating and cool- ing unit. The installer must assure that these instructions are made available to the consumer and with instructions to retain them for future reference.

1.This equipment is not to be used for temporary heating of buildings or structures under construction.

PRECEDING INSTALLATION

1.Remove the two screws holding the brackets in the front, rear and compressor side fork-lift slots.

Bracket

Turn down

Screws

 

FIGURE 1 - UNIT SHIPPING BRACKET

2.Turn each bracket toward the ground and the protective plywood covering will drop to the ground.

3.Remove the condenser coil external protective covering prior to operation.

4.Remove the toolless doorknobs and instruction packet prior to installation.

Condenser

Coil External

Protective

Covering

Barometric Relief Hood in Shipping Loca- tion (if included)

FIGURE 2 - CONDENSER COIL COVERING

This product must be installed in strict compliance with the enclosed installation instructions and any applica- ble local, state and national codes including, but not limited to, building, electrical, and mechanical codes.

Toolless

Doorknobs

Installation

Instruction

Packet

FIGURE 3 - COMPRESSOR SECTION

LIMITATIONS

These units must be installed in accordance with the follow- ing:

In U.S.A.:

1.National Electrical Code, ANSI/NFPA No. 70 - Latest Edition

2.Local building codes

3.Local electric utility requirements

In Canada:

1.Canadian Electrical Code, CSA C22.1

2.Installation Codes, CSA - B149.1.

3.Local plumbing and waste water codes, and

4.Other applicable local codes.

Refer to Tables 2 & 3 for unit application data.

If components are to be added to a unit to meet local codes, they are to be installed at the dealer’s and/or customer’s expense.

Size of unit for proposed installation should be based on heat loss/heat gain calculation made according to the methods of Air Conditioning Contractors of America (ACCA).

This furnace is not to be used for temporary heating of build- ings or structures under construction.