TABLE 8: ELECTRICAL DATA - 7-1/2 TON HP

66307-YIM-B-0606

TABLE 8: ELECTRICAL DATA - 7-1/2 TON HP

 

 

 

OD

Supply Air

Pwr

 

 

 

 

 

MCA

 

Max Fuse

Max Fuse Size

 

 

 

 

 

 

Minimum Circuit

with Power

 

Compressors

Fan

BLower

Exh

 

 

 

Size*

w/Pwr. Exh.*

 

 

 

 

Exhaust

Voltage

 

 

Motors

Motor FLA

Motor

Electric Heater

Actual

Heater

Ampacity (Amps)

(Amps)

(Amps)

 

 

(Amps)

 

 

 

 

 

 

 

Model No.

Kw

Amps

 

 

 

 

 

 

 

 

 

 

RLA

LRA

FLA

1.5 HP

2 HP

FLA

 

 

 

1.5 HP

2 HP

1.5 HP

 

2 HP

1.5 HP

2 HP

1.5 HP

2 HP

 

ea

ea

ea

(1.1 kW)

(1.5 kW)

 

 

 

(1.1 kW)

(1.5 kW)

(1.1 kW)

(1.5 kW)

(1.1 kW)

(1.5 kW)

(1.1 kW)

(1.5 kW)

 

 

 

 

 

 

 

None

-

-

25.2

26.1

27.4

 

28.3

30

30

35

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04520950

5.6

8.5

35.8

36.7

38.0

 

38.9

40

40

40

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

380

8.3

62

1.1

4.3

5.2

2.2

2TP04521850

11.3

17.2

46.6

47.5

48.8

 

49.7

50

50

50

50

 

 

 

 

 

 

 

2TP04522450

15.0

22.8

53.7

54.6

55.9

 

56.8

60

60

60

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04523650

21.3

32.4

65.6

66.5

67.8

 

68.7

70

70

70

70

 

 

 

 

 

 

 

None

-

-

25.2

26.1

27.4

 

28.3

30

30

35

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04520950

6.7

9.3

36.8

37.7

39.0

 

39.9

40

40

40

45

415

8.3

62

1.1

4.3

5.2

2.2

2TP04521850

13.5

18.8

48.7

49.6

50.9

 

51.8

50

50

60

60

 

 

 

 

 

 

 

2TP04522450

17.9

24.9

56.3

57.2

58.5

 

59.4

60

60

60

60

 

 

 

 

 

 

 

2TP04523650

25.4

35.3

69.3

70.2

71.5

 

72.4

70

80

80

80

*. Maximum HACR breaker of the same amp size is acceptable.

TABLE 9: ELECTRICAL DATA - 10 TON HP

 

 

 

OD

Supply Air

Pwr

 

 

 

 

 

MCA

Max Fuse

Max Fuse Size

 

 

 

 

 

 

Minimum Circuit

with Power

 

Compressors

Fan

BLower

Exh

 

 

 

Size*

w/Pwr. Exh.*

 

 

 

 

Exhaust

Voltage

 

 

Motors

Motor FLA

Motor

Electric Heater

Actual

Heater

Ampacity (Amps)

(Amps)

(Amps)

 

 

(Amps)

 

 

 

 

 

 

 

Model No.

Kw

Amps

 

 

 

 

 

 

 

 

 

RLA

LRA

FLA

2 HP

4HP

FLA

 

 

 

2 HP

4 HP

2 HP

4 HP

2 HP

4 HP

2 HP

4 HP

 

ea

ea

ea

(1.5 kW)

(3 kW)

 

 

 

(1.5 kW)

(3 kW)

(1.5 kW)

(3 kW)

(1.5 kW)

(3 kW)

(1.5 kW)

(3 kW)

 

 

 

 

 

 

 

 

 

 

 

 

None

--

--

25.6

27.9

27.8

30.1

30

35

35

35

 

 

 

 

 

 

 

2TP04521850

11.3

17.2

47.1

49.4

49.3

51.6

50

50

50

60

380

8.1

73.0

1.1

5.2

7.5

2.2

2TP04522450

15.0

22.8

54.1

56.4

56.3

58.6

60

60

60

60

 

 

 

 

 

 

 

2TP04523650

21.3

32.4

66.1

68.4

68.3

70.6

70

70

70

80

 

 

 

 

 

 

 

2HP04535450

33.8

51.4

70.7

73.6

73.4

76.3

80

80

80

80

 

 

 

 

 

 

 

None

--

--

25.6

27.9

27.8

30.1

30

35

35

35

 

 

 

 

 

 

 

2TP04521850

13.5

18.8

49.1

51.4

51.3

53.6

50

60

60

60

415

8.1

73.0

1.1

5.2

7.5

2.2

2TP04522450

17.9

24.9

56.8

59.1

59.0

61.3

60

60

60

70

 

 

 

 

 

 

 

2TP04523650

25.4

35.3

69.8

72.1

72.0

74.3

70

80

80

80

 

 

 

 

 

 

 

2HP04535450

40.4

56.2

76.8

79.6

79.5

82.4

80

80

80

90

*. Maximum HACR breaker of the same amp size is acceptable.

†.Only 25.4 kW of electric heat can be simultaneously energized with the mechanical heating. The full 40.4 kW operates only if both compressors are locked out.