INSTALLATION MANUAL - 50 Hz
SINGLE PACKAGE HEAT PUMP HIGH EFFICIENCY BP090 and 120 (7-1/2 and 10 TON)
66307-YIM-B-0606
CONTENTS
NOTES, CAUTIONS AND WARNINGS
TABLE OF CONTENTS
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . 39
LIST OF FIGURES
LIST OF TABLES
GENERAL
SAFETY CONSIDERATIONS
INSPECTION
REFERENCE
RENEWAL PARTS
APPROVALS
66307-YIM-B-0606
7.5-10.0 Ton York
Unitary Products Group 7
NOMENCLATURE
B P 090 C00 A 7 A AA 3 0 1 2 4 A
Model Number Nomenclature
INSTALLATION
INSTALLATION SAFETY INFORMATION
FIGURE 3 - COMPRESSOR SECTION
PRECEDING INSTALLATION
LIMITATIONS
LOCATION
FIGURE 4 - PREDATOR COMPONENT LOCATION
TABLE 1: UNIT TEMPERATURE LIMITATIONS
TABLE 2: UNIT VOLTAGE LIMITATIONS
RIGGING AND HANDLING
FIGURE 5 - UNIT 4 POINT LOAD
TABLE 3: UNIT WEIGHTS
TABLE 4: 4 POINT LOAD WEIGHT
TABLE 5: 6 POINT LOAD WEIGHT
CLEARANCES
shrubs should not obstruct condenser air discharge outlet.
DETAIL B
FIGURE 8 - UNIT DIMENSIONS
Page
N O T E : ( X X X ) i n d i c a t e s m i l l i m e t e r s
DUCTWORK
FIGURE 10 - REAR DUCT DIMENSIONS
DUCT COVERS
FIGURE 11 - PREDATOR ROOF CURB DIMENSIONS
F R O N T
FIGURE 13 - SIDE PANELS WITH HOLE PLUGS
FIGURE 12 - SUNLINE TO PREDATOR TRANSITION ROOF CURBS
14 Unitary Products Group
CONDENSATE DRAIN
COMPRESSORS
FIGURE 16 - CONDENSATE DRAIN
FILTERS
THERMOSTAT WIRING
POWER WIRING DETAIL
FIGURE 17 - ELECTRONIC THERMOSTAT FIELD WIRING
FIGURE 18 - FIELD WIRING 24 VOLT THERMOSTAT
U N I T C O N T R O L B O A R D
FIGURE 19 - FIELD WIRING DISCONNECT
TABLE 8: ELECTRICAL DATA - 7-1/2 TON HP
TABLE 9: ELECTRICAL DATA - 10 TON HP
FACTORY INSTALLED OPTIONS/ FIELD INSTALLED ACCESSORIES
TABLE 10: PHYSICAL DATA
ECONOMIZER AND POWER EXHAUST SET POINT ADJUSTMENTS AND INFORMATION
TABLE 11: ELECTRIC HEAT MINIMUM SUPPLY AIR
FIGURE 20 - ENTHALPY SET POINT CHART
+
PHASING
FIGURE 21 - HONEYWELL ECONOMIZER CONTROL W7212
BLOWER ROTATION
BELT TENSION
FIGURE 22 - BELT ADJUSTMENT
TABLE 13: BLOWER PERFORMANCE 7-1/2 TON STANDARD MOTOR - SIDE DUCT (IMPERIAL)
TABLE 14: BLOWER PERFORMANCE 7-1/2 TON STANDARD MOTOR - SIDE DUCT (METRIC)
TABLE 15: BLOWER PERFORMANCE 7-1/2 TON OPTIONAL MOTOR - SIDE DUCT (IMPERIAL)
TABLE 16: BLOWER PERFORMANCE 7-1/2 TON OPTIONAL MOTOR - SIDE DUCT (METRIC)
TABLE 17: BLOWER PERFORMANCE 10 TON STANDARD MOTOR - SIDE DUCT (IMPERIAL)
TABLE 18: BLOWER PERFORMANCE 10 TON STANDARD MOTOR - SIDE DUCT (METRIC)
TABLE 19: BLOWER PERFORMANCE 10 TON OPTIONAL MOTOR - SIDE DUCT (IMPERIAL)
TABLE 20: BLOWER PERFORMANCE 10 TON OPTIONAL MOTOR - SIDE DUCT (METRIC)
TABLE 21: BLOWER PERFORMANCE 7-1/2 TON STANDARD MOTOR - DOWNSHOT (IMPERIAL)
TABLE 22: BLOWER PERFORMANCE 7-1/2 TON STANDARD MOTOR - DOWNSHOT (METRIC)
TABLE 23: BLOWER PERFORMANCE 7-1/2 TON OPTIONAL MOTOR - DOWNSHOT (IMPERIAL)
TABLE 24: BLOWER PERF OR MANCE 7-1/2 TON OPTIONAL MOTOR - DOWNSHOT (METRIC)
TABLE 25: BLOWER PERFORMANCE 10 TON STANDARD MOTOR - DOWNSHOT (IMPERIAL)
TABLE 26: BLOWER PERFORMANCE 10 TON STANDARD MOTOR - DOWNSHOT (METRIC)
TABLE 27: BLOWER PERFORMANCE 10 TON OPTIONAL MOTOR - DOWNSHOT (IMPERIAL)
TABLE 28: BLOWER PERFORMANCE 10 TON OPTIONAL MOTOR - DOWNSHOT (METRIC)
TABLE 29: INDOOR BLOWER SPECIFICATIONS
AIR BALANCE
CHECKING AIR QUANTITY
SUPPLY AIR DRIVE ADJUSTMENT
()
FIGURE 23 - DRY COIL DELTA P
()
32 Unitary Products Group
TABLE 30: ADDITIONAL STATIC RESISTANCE - IMPERIAL
CFM Cooling Only*Economizer Electric Heat KW 9 18243654
TABLE 31: ADDITIONAL STATIC RESISTANCE - METRIC
M3S Cooling Only *Economizer Electric Heat KW 9 18243654
OPERATION
SEQUENCE OF OPERATIONS OVERVIEW
COOLING SEQUENCE OF OPERAT I ON
TABLE 32: MOTOR SHEAVE DATUM
COOLING OPERATION ERRORS
SAFETY CONTROLS
COMPRESSOR PROTECTION
HEATING SEQUENCE OF OPER AT I ON
ELECTRIC HEAT OPERATION ERRORS
ELECTRIC HEAT ANTICIPATOR SETPOINTS
START-UP
PRESTART CHECK LIST
TABLE 33: ELECTRIC HEAT LIMIT SETTING
TABLE 34: HEAT PUMP ANTICIPATOR SETPOINTS
OPERATING INSTRUCTIONS
POST START CHECK LIST
SUPERHEAT CHARGING METHOD
TABLE 35: SUPERHEAT CHARGING
TABLE 36: COOLING SUPERHEAT 7-1/2 TON
TROUBLESHOOTING
PREDA TOR
TABLE 37: COOLING SUPERHEAT 10 TON
FIGURE 24: UNIT CONTROL BOARD
TABLE 38: UNIT CONTROL BOARD FLASH CODES
COOLING TROUBL ESHO OTIN G GUI DE