NOMENCLATURE

66307-YIM-B-0606

NOMENCLATURE

7.5-10.0 Ton York® Model Number Nomenclature

B P 090 C00 A 7 A AA 3 0 1 2 4 A

Product Category

B = HP, Single Pkg., R-22

Product Identifier

P = 9.3-10.6 EER HP

Nominal Cooling Capacity

090 = 7.5 Ton

120 = 10.0 Ton

Heat Type and Nominal Heat Capacity

C00 = Cooling Only. No heat installed

Electric Heat Options

E09 = 9 KW

E18 = 18 KW

E24 = 24 KW

E36 = 36 KW

E54 = 54 KW

Airflow

A = Std. Motor

B = Std. Motor/Econo./Barometric Relief (Downflow

Only)

C = Std. Motor/Econo./Power Exhaust (Downflow Only)

D = Std. Motor/Motorized Damper (Downflow Only)

E = Std. Motor/Horizontal Economizer (No Baro.)

F = Std. Motor/Slab Econo./Power Exhaust

(Downflow Only)

G = Std. Motor/Slab Econo./Barometric Relief

(Downflow Only)

N = Hi Static Mtr.

P = Hi Static Mtr./Econo./Barometric Relief

(Downflow Only)

Q = Hi Static Mtr./Econo./Power Exhaust

(Downflow Only)

R = Hi Static Mtr./Motorized Damper (Downflow Only)

S = Hi Static Mtr./Horizontal Economizer (No Baro.)

T = Hi Static Mtr./Slab Econo./Power Exhaust

(Downflow Only)

U = Hi Static Mtr./Slab Econo./Barometric Relief

(Downflow only)

Voltage

7 = 380/415-3-50

Product Style

A = Style A

B = Style B

C = Style C

Configuration Options (not required for all units)

These four digits will not be assigned until a quote is requested, or an order placed.

SS Drain Pan

Honeywell Controller, DFS, APS

Simplicity IntelliComfort Controller

Simplicity IntelliComfort Controller w/ModLinc

2" Pleated filters

BAS Ready Unit with Belimo Economizer

Shipping Bag

Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned

 

 

Product Generation

 

 

 

 

 

 

3

= Third Generation

 

 

4

= Fourth Generation

 

 

 

 

 

 

 

 

 

 

 

 

Additional Options

AA = None

RC = Coil Guard, Shipping Bag & American Flag

AB = Phase Monitor

TA = Technicoat Condenser Coil

AC = Coil Guard

TJ = Technicoat Evaporator Coil

AD = Dirty Filter Switch

TS = Technicoat Evaporator & Condenser Coils

AE = Phase Monitor & Coil Guard

 

AF = Phase Monitor & Dirty Filter Switch

 

AG = Coil Guard & Dirty Filter Switch

 

AH = Phase Monitor, Coil Guard & Dirty Filter Switch

 

 

 

ZZ= If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18.

Installation Options

A = No Options Installed

B = Option 1

C = Option 2

D = Options 1 & 2

E = Option 3

F = Option 4

G = Options 1 & 3

H = Options 1 & 4

J = Options 1, 2 & 3

K = Options 1, 2, & 4

L = Options 1,3 & 4

M = Options 1, 2, 3, & 4

N = Options 2 & 3

P = Options 2 & 4

Q = Options 2, 3, & 4

R = Options 3 & 4

S = Option 5

T = Options 1 & 5

U = Options 1, 3, & 5

V = Options 1, 4, & 5

W = Options 1, 3, 4, & 5

X = Options 3 & 5

Y = Options 4 & 5

Z = Options 3, 4 & 5

Options

1 = Disconnect

2= Non-Pwr'd Conv. Outlet

3 = Smoke Detector S.A.

4 = Smoke Detector R.A.

5 = Pwr'd Conv. Outlet

Unitary Products Group