Pre-installation

Checklist

WARNING

Fiberglass Wool!

Product contains fiberglass wool. Disturbing the insulation in this product during installation, maintenance or repair will expose you to airborne particles of glass wool fibers and ceramic fibers known to the state of California to cause cancer through inhalation. Glass wool fibers may also cause respiratory, skin or eye irritation.

Jobsite Inspection

Always perform the following checks before accepting a unit:

1.Verify that the nameplate data matches the data on the sales order and bill of lading (including electrical data).

2.Verify that the power supply complies with the unit nameplate specifica- tions.

3.Visually inspect the exterior of the unit, for signs of shipping damage. Do not sign the bill of lading accepting the unit(s) until inspection has been com- pleted. Check for damage promptly after the unit(s) are unloaded. Once the bill of lading is signed at the jobsite, the unit(s) are now the property of the SOLD TO party and future freight claims MAY NOT be accepted by the freight company.

4.Verify that the refrigerant charge has been retained during shipment by use of gauges. Schrader taps are located internal to the cabinet.

5.After assuring that charge has been retained, reinstall the schrader caps to assure that refrigerant leakage does not occur.

WARNING

Microbial Growth!

Wet interior unit insulation can become an amplification site for microbial growth (mold), which may cause odors and serious health related indoor air quality problems. If there is evidence of microbial growth (mold) on the interior insulation, remove or replace the insulation prior to operating the system. Failure to remove microbial growth could result in serious health problems.

Jobsite Storage

This unit is intended for indoor use only. To protect the unit from damage due to the elements, and to prevent possible IAQ contaminant sources from growing, the unit should be stored indoors. If indoor storage is not possible, the following provisions for outdoor storage must be met:

1.Place the unit(s) on a dry surface or raise above the ground to assure ade- quate air circulation beneath the unit.

2.Cover the unit(s) with a water proof tarp to protect them from the elements.

3.Make provisions for continuous venting of the covered units to prevent moisture from standing on the unit(s) surfaces. Wet interior unit insulation can become an amplification site for microbial growth (mold) which has been determined to be a cause of odors and serious health related indoor air quality problems.

4.Store units in the normal UP orientation to maintain oil in the compressor.

5.Horizontal units may be stacked no more than three units high. Do not stack the vertical unit configurations.

4

WSHP-SVX01D-EN

Page 4
Image 4
Trane GEH, GEV manual Pre-installation Checklist, Fiberglass Wool

GEV, GEH specifications

Trane has long been a leader in the HVAC industry, and their GEH and GEV series of heat pumps are a testament to their commitment to innovation and efficiency. These models are designed to provide substantial energy savings while maintaining exceptional performance, making them ideal choices for both residential and commercial applications.

The Trane GEH and GEV heat pumps feature advanced variable-speed technology, which allows them to adjust their output to match the current heating or cooling demand. This adaptability not only enhances comfort by maintaining a consistent indoor temperature but also leads to significant energy savings by reducing unnecessary energy consumption during partial-load conditions. By running more efficiently at lower speeds, these units reduce wear and tear on components, extending the lifespan of the system.

One of the defining characteristics of the GEH and GEV models is their high SEER (Seasonal Energy Efficiency Ratio) and HSPF (Heating Seasonal Performance Factor) ratings. These ratings demonstrate the units' ability to provide efficient heating and cooling throughout the year, contributing to lower energy bills. The use of R-410A refrigerant is another key feature, as it is both environmentally friendly and efficient, ensuring that these systems meet stringent regulatory standards while delivering reliable performance.

Installation flexibility is another highlight of the Trane GEH and GEV series. These units are designed to work seamlessly with existing HVAC systems, making retrofitting straightforward. Their compact design allows for easy placement, even in tight spaces, without compromising performance. Additionally, Trane's commitment to quality is evident in the construction of these heat pumps, as they are built to withstand harsh weather conditions and provide reliable service year after year.

Moreover, both the GEH and GEV models are equipped with integrated smart controls that simplify operation and maintenance. These controls allow homeowners and facility managers to monitor energy usage, adjusting settings remotely and scheduling maintenance checks to maximize efficiency. This technology not only enhances user experience but also promotes energy conservation through intelligent management.

In summary, Trane's GEH and GEV heat pumps stand out for their variable-speed technology, high efficiency ratings, installation flexibility, and smart controls. These features make them an ideal solution for those seeking a reliable, energy-efficient heating and cooling option, reflecting Trane's dedication to performance and sustainability.