Electrical

Requirements

E7-Electrical performance (continued)

Model No.

GEV 180

GEV 240

GEV 300

Volts

Total

 

FLA

208/60/3

59.4

230/60/3

58.2

380-420/50/3

27.4

460/60/3

28.1

575/60/3

21.9

208/60/3

66

230/60/3

64

380-420/50/3

29.5

460/60/3

31

575/60/3

23.8

208/60/3

75

230/60/3

71.6

380-420/50/3

33.3

460/60/3

34.8

575/60/3

26.8

208/60/3

79.4

230/60/3

77.4

380-420/50/3

38.9

460/60/3

35.2

575/60/3

27.6

208/60/3

88.4

230/60/3

85

380-420/50/3

42.7

460/60/3

39

575/60/3

30.6

208/60/3

96.4

230/60/3

91.4

380-420/50/3

46.4

460/60/3

42.2

575/60/3

33.4

208/60/3

108.2

230/60/3

104

380-420/50/3

50.9

460/60/3

48.5

575/60/3

38.6

208/60/3

110.2

230/60/3

108.2

380-420/50/3

44.7

460/60/3

46.2

575/60/3

36.8

208/60/3

119.2

230/60/3

115.8

380-420/50/3

48.5

460/60/3

50

575/60/3

39.8

208/60/3

127.2

230/60/3

122.2

380-420/50/3

52.2

460/60/3

53.2

575/60/3

42.6

208/60/3

139

230/60/3

134.8

380-420/50/3

56.7

460/60/3

59.5

575/60/3

47.8

Comp

RLA (ea)

25.00

25.00

12.00

12.00

9.30

25.00

25.00

12.00

12.00

9.30

25.00

25.00

12.00

12.00

9.30

31.70

31.70

16.70

14.10

11.20

31.70

31.70

16.70

14.10

11.20

31.70

31.70

16.70

14.10

11.20

31.70

31.70

16.70

14.10

11.20

47.10

47.10

19.60

19.60

15.80

47.10

47.10

19.60

19.60

15.80

47.10

47.10

19.60

19.60

15.80

47.10

47.10

19.60

19.60

15.80

Comp

LRA (ea)

164.0

164.0

90.5

100.0

78.0

164.0

164.0

90.5

100.0

78.0

164.0

164.0

90.5

100.0

78.0

232.0

261.0

133.0

112.0

92.0

232.0

261.0

133.0

112.0

92.0

232.0

261.0

133.0

112.0

92.0

232.0

261.0

133.0

112.0

92.0

245.0

245.0

118.0

125.0

100.0

245.0

245.0

118.0

125.0

100.0

245.0

245.0

118.0

125.0

100.0

245.0

245.0

118.0

125.0

100.0

No. of

Compres.

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

Cmp

MCC

35.0

35.0

17.0

17.0

13.0

35.0

35.0

17.0

17.0

13.0

35.0

35.0

17.0

17.0

13.0

49.5

49.5

26.0

22.0

17.5

49.5

49.5

26.0

22.0

17.5

49.5

49.5

26.0

22.0

17.5

49.5

49.5

26.0

22.0

17.5

66.0

66.0

27.5

27.5

22.2

66.0

66.0

27.5

27.5

22.2

66.0

66.0

27.5

27.5

22.2

66.0

66.0

27.5

27.5

22.2

Blower

Blower

Motor

Motor

FLA

HP

9.403

8.203

3.402

4.103

3.303

16.005

14.005

5.503

7.005

5.205

25.007.5

21.607.5

9.305

10.807.5

8.207.5

16.005

14.005

5.503

7.005

5.205

25.007.5

21.607.5

9.305

10.807.5

8.207.5

33.0010

28.0010

13.007.5

14.0010

11.0010

44.8015

40.6015

17.5010

20.3015

16.2015

16.005

14.005

5.503

7.005

5.205

25.007.5

21.607.5

9.305

10.807.5

8.207.5

33.0010

28.0010

13.007.5

14.0010

11.0010

44.8015

40.6015

17.5010

20.3015

16.2015

Fan

Motor

Num

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Minimum Maximum Electric

Circuit Overcur- Heat

Ampacity rent kW Protec-

tive

Device

65.790

64.580

30.440

31.140

24.230

72.390

70.390

32.540

34.045

26.135

81.3100

77.9100

36.345

37.845

29.135

87.4110

85.4110

43.150

38.750

30.440

96.4125

93.0110

46.960

42.550

33.440

104.7125

99.4125

50.660

45.750

36.245

119.5150

114.2150

55.370

53.670

42.750

122.0150

120.0150

49.660

51.170

40.850

131.0175

127.6150

53.470

54.970

43.850

139.0175

134.0175

57.170

58.170

46.660

150.8175

146.6175

61.680

64.680

51.960

Electric

Heat

Amps

E8-Electrical minimum and maximum

E8-Electrical minimum and maximum (continued)

Digit 8

0

1

2

3

4

Rated Voltage

115

208

230

208

460

HZ

60

60

60

60

60

Ph

1

1

1

3

3

Minimum

Maximum

 

Utilization

Utilization

 

Voltage

Voltage

 

104

126

 

197

229

 

207

253

 

187

229

 

 

 

 

414

506

 

 

 

 

Digit 8

5

6

7

8

9

Rated

Voltage

575

220-240

265

230

380-415

HZ

60

50

60

60

60

Ph

3

1

1

3

3

Minimum

Maximum

Utilization

Utilization

Voltage

Voltage

518

633

198

264

239

292

207

253

342

456

 

 

7 2

WSHP-SVX01D-EN

Page 72
Image 72
Trane GEH, GEV manual E7-Electrical performance, E8-Electrical minimum and maximum

GEV, GEH specifications

Trane has long been a leader in the HVAC industry, and their GEH and GEV series of heat pumps are a testament to their commitment to innovation and efficiency. These models are designed to provide substantial energy savings while maintaining exceptional performance, making them ideal choices for both residential and commercial applications.

The Trane GEH and GEV heat pumps feature advanced variable-speed technology, which allows them to adjust their output to match the current heating or cooling demand. This adaptability not only enhances comfort by maintaining a consistent indoor temperature but also leads to significant energy savings by reducing unnecessary energy consumption during partial-load conditions. By running more efficiently at lower speeds, these units reduce wear and tear on components, extending the lifespan of the system.

One of the defining characteristics of the GEH and GEV models is their high SEER (Seasonal Energy Efficiency Ratio) and HSPF (Heating Seasonal Performance Factor) ratings. These ratings demonstrate the units' ability to provide efficient heating and cooling throughout the year, contributing to lower energy bills. The use of R-410A refrigerant is another key feature, as it is both environmentally friendly and efficient, ensuring that these systems meet stringent regulatory standards while delivering reliable performance.

Installation flexibility is another highlight of the Trane GEH and GEV series. These units are designed to work seamlessly with existing HVAC systems, making retrofitting straightforward. Their compact design allows for easy placement, even in tight spaces, without compromising performance. Additionally, Trane's commitment to quality is evident in the construction of these heat pumps, as they are built to withstand harsh weather conditions and provide reliable service year after year.

Moreover, both the GEH and GEV models are equipped with integrated smart controls that simplify operation and maintenance. These controls allow homeowners and facility managers to monitor energy usage, adjusting settings remotely and scheduling maintenance checks to maximize efficiency. This technology not only enhances user experience but also promotes energy conservation through intelligent management.

In summary, Trane's GEH and GEV heat pumps stand out for their variable-speed technology, high efficiency ratings, installation flexibility, and smart controls. These features make them an ideal solution for those seeking a reliable, energy-efficient heating and cooling option, reflecting Trane's dedication to performance and sustainability.