GE PGP989 warranty GAS Supply, Turn OFF GAS Electric Supply, Convert Surface Burners

Page 2

Conversion Instructions

GAS SUPPLY

With the installation of this conversion kit, the cooktop

should operate on LP gas at 10of water column

pressure.

The pressure regulator must be connected in series

with the manifold of the cooktop and must remain in

series with the supply line. For proper operation, the

maximum inlet pressure to the regulator must be no

1CONVERT SURFACE BURNERS

AFirst remove, convert and replace the left side surface burners and then the right side surface burners.

Remove the grates, burner caps and burner heads. Remove the screws securing the burner bases

to the burners. Pull out the electrodes without removing the electrode leads.

more than 14water column pressure for LP gas.

When checking the regulator, the inlet pressure must

be at least 1greater than the regulator output

setting. If the regulator is set for 10of water column

pressure, the inlet pressure must be at least 11.

IMPORTANT – Disconnect the cooktop and the individual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig. Isolate the cooktop from the gas supply piping system by closing the individual manual shut-off valve to the cooktop during any pressure

Grate

Burner cap

Burner head

Electrode

Burner base screw (2)

Burner base

testing of the gas supply piping system at test pressures equal to or greater than 1/2 psig.

TURN OFF GAS AND

ELECTRIC SUPPLY

BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT THE SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL SUPPLY FROM THE COOKTOP.

Electrical supply

Shut-off valve

BRemove the brass orifice spud in the chimney of each burner using a 9/32(7 mm) nutdriver.

CInstall the LP orifice spuds in their correct positions by number. Note: The LP orifices are shorter than the natural gas orifices.

84

71

L

L

84

99

L

L

Front

LP (Propane) Gas 10W.C.P.

Burner Output Rating in BTU/HR

Location

BTUs

Orifice Size

LF, LR

8,500

0.84 Lmm

 

 

 

RR

5,500

0.71 Lmm

 

 

 

RF

11,000

0.99 Lmm

High Altitude Orifice Conversion Kit

Use for cooktop operation at elevations above 5000 ft. (1500m). Specify kit for Natural Gas or LP Gas when ordering:

Natural Gas High Altitude Orifice Conversion Kit

.........WB28X10114

LP High Altitude Orifice Conversion Kit

WB28X10115

2

Image 2
Contents Important Save these For Your SafetyBefore YOU Begin Important Observe allConvert Surface Burners GAS SupplyTurn OFF GAS Electric Supply LP Propane Gas 10″ W.C.PConvert the Pressure Regulator Test for LeaksCheck Ignition Perform leak test per the following instructionsFlame Stability Test Adjust the LOW Flame Simmer SettingConverting Back to Natural GAS Flame RecheckImportante Guarde estas Antes DE ComenzarPara SU Seguridad Herramientas NecesariasGas LP Propano P.C.A de Suministro DE GASConversión DE Quemadores DE Superficie Kit de conversión de orificios en altitudes elevadasControle EL Encendido Conversión DEL Regulador DE PresiónPrueba DE Pérdidas Que haya puntas amarillas en los conos externosNueva verificación de la llama Conversión DE Vuelta a GAS NaturalPrueba de estabilidad de llama Gas natural P.C.A de
Related manuals
Manual 72 pages 29.09 Kb