GE PGP989 Adjust the LOW Flame Simmer Setting, Converting Back to Natural GAS, Flame Recheck

Page 4

Conversion Instructions

5ADJUST THE LOW FLAME (SIMMER) SETTING

The top burner valves have low flame/simmer adjustment screws in the center of the control shafts. A flashlight may be needed to locate the screw. A small, thin-blade screwdriver (approximately 1/8blade width) is needed to access the screw.

ALight two other burners and set the knobs to a medium to high setting.

BLight the burner to be adjusted and turn the knob to LOW.

CRemove the knob and insert a screwdriver into the valve shaft.

DTurn the adjustment screw until the flame reaches the desired size.

EPerform a flame stability test.

Flame Stability Test

Test 1: With the downdraft vent fan on HI, turn the burner knob from HI to LOW quickly. If the LOW flame goes out, increase the flame size and test again.

Test 2: With the burner on the LOW setting, open and close the cabinet door under the cooktop. If the flame is extinguished by the air currents created by the door movement, increase

the flame height and test again.

Flame Recheck

After the adjustment is made, turn all burners off. Ignite each burner individually. Observe the flame at the HI position. Rotate the valve to the LOW position and be sure the flame size decreases as the valve is rotated counterclockwise.

CONVERTING BACK TO NATURAL GAS

Reverse the procedures for converting to LP, locating the orifices as follows:

150

122

N

N

150

169

N

N

Front

Natural Gas 4W.C.P.

Burner Output Rating in BTU/HR

Location

BTUs

Orifice Size

LF, LR

9,100

1.50 Nmm

 

 

 

RR

5,500

1.22 Nmm

 

 

 

RF

11,500

1.69 Nmm

High Altitude Orifice Conversion Kit

Use for cooktop operation at elevations above 5000 ft. (1500m). Specify kit for Natural Gas or LP Gas when ordering:

Natural Gas High Altitude Orifice Conversion Kit

.........WB28X10114

LP High Altitude Orifice Conversion Kit

WB28X10115

4

Image 4
Contents For Your Safety Before YOU BeginImportant Save these Important Observe allGAS Supply Turn OFF GAS Electric SupplyConvert Surface Burners LP Propane Gas 10″ W.C.PTest for Leaks Check IgnitionConvert the Pressure Regulator Perform leak test per the following instructionsAdjust the LOW Flame Simmer Setting Converting Back to Natural GASFlame Stability Test Flame RecheckAntes DE Comenzar Para SU SeguridadImportante Guarde estas Herramientas NecesariasSuministro DE GAS Conversión DE Quemadores DE SuperficieGas LP Propano P.C.A de Kit de conversión de orificios en altitudes elevadasConversión DEL Regulador DE Presión Prueba DE PérdidasControle EL Encendido Que haya puntas amarillas en los conos externosConversión DE Vuelta a GAS Natural Prueba de estabilidad de llamaNueva verificación de la llama Gas natural P.C.A de