GE 164D4290P393 Remove Duct Knockout, For 7″ Round Vertical Ducted Discharge Installations only

Page 12

Installation Instructions

7REMOVE DUCT KNOCKOUT

If recirculating, non-vented ductless (JN327 and RN328, and optional for JV347 and JV367 models only), skip to Step 10 D and proceed.

Using a flat blade screwdriver, remove the appropriate duct knockout from the top or back of the hood.

8FOR 314X 10RECTANGULAR

DUCTED DISCHARGE

INSTALLATIONS ONLY:

Attach exhaust adaptor/damper over the appropriate knockout opening (for vertical or horizontal, depending on installation) with two exhaust adaptor screws. Make sure damper pivot is nearest to top/back

314x 10Rectangular vertical discharge. Remove top rectangular duct knockout only.

7 Round vertical discharge. Remove circular duct knockout only.

314x 10Rectangular horizontal discharge. Remove rear rectangular duct knockout only.

edge of hood. Remove tape from damper flap.

 

Exhaust adaptor/damper

 

Up to 1side-to-

(vertical discharge position)

Tape

 

side adjustment

 

 

Pivot

Top/back edge

(depending on

installation)Exhaust adaptor/damper (horizontal discharge position)

NOTE: The exhaust adaptor/damper can be installed up to 1 inch on either side of the hood center to accommodate off-center ductwork. In extreme off- center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp.

9FOR 7ROUND VERTICAL

DUCTED DISCHARGE

INSTALLATIONS ONLY:

Bend up the duct alignment ears in preparation for later attachment of the 7″ duct.

Attachment ear tabs

12

Image 12
Contents Range Hoods Safety Precautions Avertissement Réduisez LE Using the hood controls Instructions Ductwork Requirements Exhaust connectionMaximum duct length Elbows, transitions, wall and roofcaps, etcDucting Chart Equivalent Feet of Duct LengthWORKSHEET-CALCULATE Total Equivalent Ductwork Length Damage SHIPMENT/INSTALLATION Mounting SpaceTools YOU will Need Parts IncludedChoose Vent Option Reverse the Baffle for Ducted Installations only Remove Wiring CoverRemove Wiring Knockout Remove Exhaust AdaptorFor 7″ Round Vertical Ducted Discharge Installations only Remove Duct KnockoutMark Holes Outside top exhaust Vertical duct-31⁄4″x 10″ RectangularOutside top exhaust Vertical duct-7″Round Outside rear exhaust Horizontal duct-31⁄4″x 10″ RectangularRUN Wires Optional Power Cord KIT JXHC1Feed in Wires CUT HolesInstall Light Bulb Follow Electrical Code Secure HoodConnect Wiring Replace Wiring CoverTroubleshooting Checklist Replace FilterPage Page GE Range Hood Warranty Consumer Support GE Appliances Website