GE 164D4290P393 installation instructions WORKSHEET-CALCULATE Total Equivalent Ductwork Length

Page 8

Installation Instructions

WORKSHEET—CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH

DUCT

EQUIVALENT NUMBER

 

 

PIECES

LENGTH

x USED

= TOTAL

314x 10

1 Ft.

x

(

)

=

Ft.

Rect.,

 

 

 

 

 

 

straight

 

 

 

 

 

 

7Round,

1 Ft.

x

(

)

=

Ft.

straight

 

 

 

 

 

 

6Round,

1 Ft.

x

(

)

=

Ft.

straight

 

 

 

 

 

 

314x 10

8.5 Ft.

x

(

)

=

Ft.

Rect. 90°

 

 

 

 

 

 

elbow

 

 

 

 

 

 

314x 10

7 Ft.

x

(

)

=

Ft.

Rect. 45°

 

 

 

 

 

 

elbow

 

 

 

 

 

 

314x 10

24 Ft.

x

(

)

=

Ft.

Rect. 90°

 

 

 

 

 

 

flat elbow

 

 

 

 

 

 

314x 10

45 Ft.

x

(

)

=

Ft.

Rect.

(7 ft. w/o

 

 

 

 

 

wall cap

damper)

x

(

)

=

Ft.

with

 

 

 

 

 

 

damper

 

 

 

 

 

 

314x 10

4.5 Ft.

x

(

)

=

Ft.

Rect. to

 

 

 

 

 

 

6round

 

 

 

 

 

 

transition

 

 

 

 

 

 

314x 10

11.5 Ft.

x

(

)

=

Ft.

Rect. to

 

 

 

 

 

 

6round

 

 

 

 

 

 

transition

 

 

 

 

 

 

90° elbow

 

 

 

 

 

 

6Round,

8 Ft.

x

(

)

=

Ft.

90° elbow

 

 

 

 

 

 

6Round,

6.5 Ft.

x

(

)

=

Ft.

45° elbow

 

 

 

 

 

 

 

Subtotal column 1

 

=

Ft.

MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of a 314″ x 10″ rectangular, 6″ or 7″ diameter round duct should not exceed 65 equivalent feet.

DUCT

EQUIVALENT

 

NUMBER

 

 

PIECES

LENGTH

x USED

= TOTAL

6Round

34 Ft.

x

(

)

=

Ft.

wall cap

(6 ft. w/o

 

 

 

 

 

with

damper)

x

(

)

=

Ft.

damper

 

 

 

 

 

 

6Round

30 Ft.

x

(

)

=

Ft.

roof cap

 

 

 

 

 

 

6Round

5.5 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

314x 10

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition

 

 

 

 

 

 

6Round

14.5 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

314x 10

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition

 

 

 

 

 

 

90° elbow

 

 

 

 

 

 

7Round,

8 Ft.

x

(

)

=

Ft.

90° elbow

 

 

 

 

 

 

7Round,

6.5 Ft.

x

(

)

=

Ft.

45° elbow

 

 

 

 

 

 

7Round

34 Ft.

x

(

)

=

Ft.

wall cap

(6 ft. w/o

 

 

 

 

 

with

damper)

x

(

)

=

Ft.

damper

 

 

 

 

 

 

7Round

30 Ft.

x

(

)

=

Ft.

roof cap

 

 

 

 

 

 

7Round

5.5 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

314x 10

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition

 

 

 

 

 

 

7Round

14.5 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

314x 10

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition,

 

 

 

 

 

 

90° elbow

 

 

 

 

 

 

 

Subtotal column 2

 

=

Ft.

 

Subtotal column 1

 

=

Ft.

Total ductwork

=

Ft.

8

Image 8
Contents Range Hoods Safety Precautions Avertissement Réduisez LE Using the hood controls Instructions Ductwork Requirements Exhaust connectionMaximum duct length Elbows, transitions, wall and roofcaps, etcDucting Chart Equivalent Feet of Duct LengthWORKSHEET-CALCULATE Total Equivalent Ductwork Length Damage SHIPMENT/INSTALLATION Mounting SpaceTools YOU will Need Parts IncludedChoose Vent Option Reverse the Baffle for Ducted Installations only Remove Wiring CoverRemove Wiring Knockout Remove Exhaust AdaptorFor 7″ Round Vertical Ducted Discharge Installations only Remove Duct KnockoutMark Holes Outside top exhaust Vertical duct-31⁄4″x 10″ RectangularOutside top exhaust Vertical duct-7″Round Outside rear exhaust Horizontal duct-31⁄4″x 10″ RectangularRUN Wires Optional Power Cord KIT JXHC1Feed in Wires CUT HolesInstall Light Bulb Follow Electrical Code Secure HoodConnect Wiring Replace Wiring CoverTroubleshooting Checklist Replace FilterPage Page GE Range Hood Warranty Consumer Support GE Appliances Website