Receiving

Upon receiving the product check to make sure all items are accounted for by referencing the packing list ensuring all items were received. Inspect each crate for shipping damage before accepting delivery. Notify the carrier if any damage is noticed. The carrier will make notification on the delivery receipt acknowledging any damage to the product. All damage should be noted on all the copies of the bill of lading which is countersigned by the delivering carrier. A Carrier Inspection Report should be filled out by the carrier upon arrival and filed with the Traffic Department. If damaged upon arrival, file claim with carrier. Any physical damage to the unit after acceptance is not the responsibility of Greenheck Fan Corporation.

Unpacking

Verify that all required parts and the correct quantity of each item have been received. If any items are missing, report shortages to your local representative to arrange for obtaining missing parts. Sometimes it is not possible that all items for the unit be shipped together due to availability of transportation and truck space. Confirmation of shipment(s) must be limited to only items on the packing list. Filters and carbon panels are shipped on separate skids in their original packaging. Do not remove factory packaging or install filters until just prior to commissioning. Remove all other shipping/packing materials including fan tie down straps.

Handling

Units are to be rigged and moved by the lifting brackets provided or by the skid when a forklift is used. Location of brackets varies by model and size. Handle in such a manner as to keep from scratching or chipping the coating. Damaged finish may reduce ability of unit to resist corrosion.

Storage

Units are protected against damage during shipment. If the unit cannot be installed and operated immediately, precautions need to be taken to prevent deterioration of the unit during storage. The user assumes responsibility of the unit and accessories while in storage. The manufacturer will not be responsible

for damage during storage. These suggestions are provided solely as a convenience to the user.

INDOOR

The ideal environment for the storage of units and accessories is indoors, above grade, in a low humidity atmosphere which is sealed to prevent the entry of blowing dust, rain, or snow. Temperatures should

be evenly maintained between 30°F (-1°C) and 110°F (43°C) (wide temperature swings may cause condensation and “sweating” of metal parts). All accessories must be stored indoors in a clean, dry atmosphere.

Remove any accumulations of dirt, water, ice, or snow and wipe dry before moving to indoor storage. To

avoid “sweating” of metal parts allow cold parts to reach room temperature. To dry parts and packages use a portable electric heater to get rid of any moisture build up. Leave coverings loose to permit air circulation and to allow for periodic inspection.

OUTDOOR

Units designed for outdoor applications may be stored outdoors, if absolutely necessary. Roads or aisles for portable cranes and hauling equipment are needed.

The unit should be placed on a level surface to prevent water from leaking into it. The unit should be elevated on an adequate number of wooden blocks so that it is above water and snow levels and has enough blocking to prevent it from settling into soft ground. Locate parts far enough apart to permit air circulation, sunlight, and space for periodic inspection. To minimize water accumulation, place all unit parts on blocking supports so that rain water will run off.

Do not cover parts with plastic film or tarps as these cause condensation of moisture from the air passing through heating and cooling cycles.

Inspection and Maintenance during Storage

While in storage, inspect equipment once per month. Keep a record of inspection and maintenance performed.

If moisture or dirt accumulations are found on parts, the source should be located and eliminated. At each inspection, rotate the fan wheel by hand ten to fifteen revolutions to distribute lubricant on motor. Every three months, the fan motor should be energized. If paint deterioration begins, consideration should be given to touch-up or repainting. Fans with special coatings may require special techniques for touch-up or repair.

Machined parts coated with rust preventive should be restored to good condition promptly if signs of rust occur. Immediately remove the original rust preventive coating with petroleum solvent and clean with lint- free cloths. Polish any remaining rust from surface with crocus cloth or fine emery paper and oil. Do not destroy the continuity of the surfaces. Wipe thoroughly clean with Tectyl® 506 (Ashland Inc.) or the equivalent. For hard to reach internal surfaces or for occasional use, consider using Tectyl® 511M Rust Preventive or WD-40® or the equivalent.

Removing from Storage

As units are removed from storage to be installed in their final location, they should be protected and maintained in a similar fashion, until the equipment goes into operation. Prior to installing the unit and system components, inspect the unit assembly to make sure it is in working order.

1.Check all fasteners, set screws on the fan, wheel, bearings, drive, motor base, and accessories for tightness.

2.Rotate the fan wheel(s), where applicable, by hand and assure no parts are rubbing.

2Grease Grabber™ Power Play Kitchen Exhaust Pollution Control System

Image 2
Contents Installation, Operation and Maintenance Manual General Safety InformationReceiving Table of Contents System Components Grease Grabber Power Play System FunctionInstallation Materials PlumbingDuct Connections Wash Cycle Unit Size Water Flow Detergent Flow Rate gpmElectrostatic Cell Wiring ElectricalInitial System Start-Up Exhaust Fan Motor WiringSystem Control Panel Wiring Component Status OperationManual versus Auto Operation Wash 2 min Wash Mode Steps Component Status Delay Period 5 minReset Mode Soak 2 minFlow Control Valve Adjustment MaintenanceAdjustments Page Plumbing and Electrical Schematics Field Wiring DiagramFan Wiring Exhaust FANGreenheck Fire Suppression Wiring Notes Maintenance Log Warranty

474754 specifications

The Greenheck Fan 474754 is an advanced ventilation solution designed for commercial and industrial applications. Known for its powerful performance and energy efficiency, this fan caters to a wide range of air movement needs, making it a preferred choice among engineers and facility managers.

One of the standout features of the Greenheck Fan 474754 is its robust construction. Made with high-quality materials, the fan is designed to withstand demanding environments while minimizing wear and tear. The housing is typically constructed from galvanized steel, resulting in outstanding durability and resistance to corrosion.

Equipped with a direct-drive motor, the fan promises lower maintenance costs and higher energy efficiency compared to traditional belt-driven models. The direct drive system eliminates the need for belts and pulleys, reducing the risk of failure and downtime. Moreover, it allows for a more compact design, making installation simpler and space-saving.

The technology behind the Greenheck Fan 474754 also emphasizes noise reduction. With fully integrated sound attenuation features, this fan operates quietly, making it suitable for environments where noise levels need to be kept to a minimum. This is particularly valuable in commercial spaces like offices, restaurants, and healthcare facilities.

Performance-wise, the Greenheck Fan 474754 is designed to deliver high static pressure capabilities, making it effective for applications that require the movement of air against significant resistance. This characteristic is critical for systems involving long duct runs or high-efficiency filters. The fan's adjustable speed motor further enhances versatility, allowing users to tailor airflow rates to their specific needs.

Furthermore, this model is equipped with advanced control options, allowing for automation and remote monitoring. Compatibility with building management systems means the fan can be integrated into an overall HVAC solution, providing users with enhanced control over their indoor environment.

In summary, the Greenheck Fan 474754 is a high-performance, energy-efficient solution ideal for various ventilation applications. Its durable construction, direct-drive motor, noise reduction capabilities, and advanced control options make it a reliable choice for those looking to optimize their air movement solutions in a range of settings. This makes it an invaluable asset for efficient and effective ventilation management.