To access the pre- and post-mesh filters and ionizing collecting cells, follow these instructions.

1.Rotate the disconnect knob on the upper right hand corner of the System Control to the OFF position. “Lock Out” the system by flipping the red lever in the handle outward and securing it with a padlock.

2.Open the access door by turning the knob on the red safety switch until the plunger is fully retracted, then unscrew the black knobs to unlatch the door.

3.Slide the metal mesh filters from the tracks

4.Thoroughly clean the metal mesh filters using hot water and a GLT-33 detergent.

5.Reinstall the filters in the tracks.

6.Remove the collector cells retaining brackets using a 7/16-inch wrench.

7.Remove the red and blue high voltage cables and jumper cables by firmly grasping the red boots and pulling them from the high voltage plugs.

8.Carefully remove a cell from the cabinet. Each 2 ft. cell weighs approximately 65 lbs., so use caution when handling. Use care not to bend or dent the collecting plates or framework.

9.Carefully inspect the cell for bent collector plates. Bent plates may be carefully straightened by hand, using needle-nose pliers.

10.Inspect the cell for residual grease that was not removed during the wash process. Excessive grease buildup indicates that the cells need to be removed from the cabinet and thoroughly cleaned manually, following the procedures under Ionizing- Collecting Cells in Maintenance.

11.Reinstall the cell to the location from which it was removed. The serrated ionizing blades of the cell must be facing upstream. There is an airflow arrow on the cell end plate.

12.Reconnect the high voltage cables, and cell retaining brackets.

13.Close the access door completely, engage the door latch, and turn the knob on the red safety switch until the plunger is fully extended.

Grease Grabber™ Power Play Kitchen Exhaust Pollution Control System 11

Image 11
Contents General Safety Information Installation, Operation and Maintenance ManualReceiving System Components Grease Grabber Power Play System Function Table of ContentsInstallation Wash Cycle Unit Size Water Flow Detergent Flow Rate gpm PlumbingDuct Connections MaterialsElectrical Electrostatic Cell WiringInitial System Start-Up Exhaust Fan Motor WiringSystem Control Panel Wiring Component Status OperationManual versus Auto Operation Soak 2 min Wash Mode Steps Component Status Delay Period 5 minReset Mode Wash 2 minFlow Control Valve Adjustment MaintenanceAdjustments Page Field Wiring Diagram Plumbing and Electrical SchematicsExhaust FAN Fan WiringGreenheck Fire Suppression Wiring Notes Warranty Maintenance Log

474754 specifications

The Greenheck Fan 474754 is an advanced ventilation solution designed for commercial and industrial applications. Known for its powerful performance and energy efficiency, this fan caters to a wide range of air movement needs, making it a preferred choice among engineers and facility managers.

One of the standout features of the Greenheck Fan 474754 is its robust construction. Made with high-quality materials, the fan is designed to withstand demanding environments while minimizing wear and tear. The housing is typically constructed from galvanized steel, resulting in outstanding durability and resistance to corrosion.

Equipped with a direct-drive motor, the fan promises lower maintenance costs and higher energy efficiency compared to traditional belt-driven models. The direct drive system eliminates the need for belts and pulleys, reducing the risk of failure and downtime. Moreover, it allows for a more compact design, making installation simpler and space-saving.

The technology behind the Greenheck Fan 474754 also emphasizes noise reduction. With fully integrated sound attenuation features, this fan operates quietly, making it suitable for environments where noise levels need to be kept to a minimum. This is particularly valuable in commercial spaces like offices, restaurants, and healthcare facilities.

Performance-wise, the Greenheck Fan 474754 is designed to deliver high static pressure capabilities, making it effective for applications that require the movement of air against significant resistance. This characteristic is critical for systems involving long duct runs or high-efficiency filters. The fan's adjustable speed motor further enhances versatility, allowing users to tailor airflow rates to their specific needs.

Furthermore, this model is equipped with advanced control options, allowing for automation and remote monitoring. Compatibility with building management systems means the fan can be integrated into an overall HVAC solution, providing users with enhanced control over their indoor environment.

In summary, the Greenheck Fan 474754 is a high-performance, energy-efficient solution ideal for various ventilation applications. Its durable construction, direct-drive motor, noise reduction capabilities, and advanced control options make it a reliable choice for those looking to optimize their air movement solutions in a range of settings. This makes it an invaluable asset for efficient and effective ventilation management.