Fisher & Paykel CG603 Gas Rate Summary, Customer Care Current Information, CG913TM, New Zealand

Page 8

Installation Instructions

Gas Rate Summary

Burners

CG603

Natural Gas

LPG

Orifice size MJ/h@1 kPa

Orifice size MJ/h@2.75 kPa

 

Auxiliary Burner (RH front)

0.85 mm

3.6 MJ/h

0.55 mm

4.0 MJ/h

 

 

Semi-Rapid Burner (LH & RH rear)

1.3 mm

8.5 MJ/h

0.8 mm

8.5 MJ/h

 

 

Wok Burner (LF front)

1.75 mm

15 MJ/h

1.00 mm

13.5 MJ/h

 

 

Rapid Burner (LH front)

1.55 mm

12 MJ/h

0.95 mm

12 MJ/h

 

CG903

 

 

 

 

 

 

Auxiliary Burner (RH front)

0.85 mm

3.6 MJ/h

0.55 mm

4.0 MJ/h

 

 

Semi-Rapid Burner (LH & RH rear)

1.3 mm

8.5 MJ/h

0.80 mm

8.5 MJ/h

 

 

Fish Burner (Centre)

1.55 mm

12 MJ/h

0.95 mm

12 MJ/h

 

 

Wok Burner (LH front)

1.75 mm

15 MJ/h

1.00 mm

13.5 MJ/h

 

GC913T

 

 

 

 

 

 

Simmer Burner (RH front)

0.85 mm

3.6 MJ/h

0.45 mm

2.7 MJ/h

 

 

Semi-Rapid Burner (LH rear)

1.22 mm

7.2 MJ/h

0.7 mm

6.2 MJ/h

 

 

Rapid Burner (LH front & RH rear)

1.45 mm

10.5 MJ/h

0.85 mm

9.3 MJ/h

 

 

Wok Burner (Centre)

1.80 mm

15.5 MJ/h

1.05 mm

14.5 MJ/h

 

CG913TM

 

 

 

 

 

 

Simmer Burner (RH front)

0.85 mm

3.6 MJ/h

0.45 mm

2.7 MJ/h

 

 

Semi-Rapid Burner (LH rear)

1.22 mm

7.2 MJ/h

0.7 mm

6.2 MJ/h

 

 

Rapid Burner (LH front & RH rear)

1.45 mm

10.5 MJ/h

0.85 mm

9.3 MJ/h

 

 

Wok Burner (Centre)

1.90 mm

16.3 MJ/h

1.10 mm

15.3 MJ/h

Customer Care

Current Information

New Zealand

Current Installation Instructions, Product

P.O. Box 58732, Greenmount, Auckland.

dimensions and specifications are available

Toll Free 0800 FP CARE (0800 37 2273)

on the Fisher & Paykel web site:

Fax

09 273 0656

www.fisherpaykel.com

Email

customer.care@fp.co.nz

Australia

 

P.O. Box 798, Cleveland, QLD 4163.

 

Toll Free 1300 650 590

 

Tel

07 3826 9100

 

Fax

07 3826 9298

 

Email

customer.care@fp.com.au

 

8

Image 8
Contents Installation Instructions NZ & AUSafety & Warnings Before You StartThese products are registered Make the bench top of a heat resistant materialCutout DimensionsProduct Clearances CG603 Series CG903 Series CG913 SeriesClearance from side edge 130 mm 120 mm 80 mm Clearance from rear edge 100 mm 90 mmInstallation Instructions Gas Supply Connection Check Natural GasLP Gas Turn on each gas valve and light each burnerMinimum Setting or Turn Down Turn on main electrical supply and light the burnersCheck all burners have good flame see ,4,5 Replace the knobGas Rate Summary Customer Care Current InformationCG913TM New Zealand