CHECKING THE GAS TYPE

PAGE 4 OF 6

GC36

Burners

NG Orifice

NG

 

LP Orifice

LP

 

 

(mm)

BTU (MJ/h)@

(mm)

BTU (MJ/h)@

 

 

0.15psi (4”H20)

 

0.41psi (11”H20)

RH Rear

1.3mm

8,000

(8.4 MJ/h)

0.8mm

8,000

(8.4 MJ/h)

LH Rear

1.3mm

8,000

(8.4 MJ/h)

0.8mm

8,000

(8.4 MJ/h)

RH Front Simmer

0.85mm

3,500

(3.47 MJ/h)

0.55mm

4,000

(4.2 MJ/h)

LH Front Wok

1.75mm

13,000 (13.7 MJ/h)

1.05mm

13,000 (13.7 MJ/h)

Center

1.45mm

9,500

(10 MJ/h)

0.85mm

9,500

(10.0 MJ/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GC901 / GC901M

Burners

NG Orifice

NG

LP Orifice

LP

 

 

(mm)

BTU (MJ/h)@

(mm)

BTU (MJ/h)@

 

 

0.15psi (4”H20)

 

0.41psi (11”H20)

RH Rear

1.3mm

8,000 (8.4 MJ/h)

0.8mm

8,200 (8.7 MJ/h)

LH Rear

1.1mm

5,800 (6.1 MJ/h)

0.7mm

5,700 (6.0 MJ/h)

RH Front Simmer

0.85mm

3,000 (3.2 MJ/h)

0.55mm

3,500 (3.7 MJ/h)

LH Front

1.3mm

8,000 (8.4 MJ/h)

0.8mm

8,200 (8.7 MJ/h)

Center (GC901)

1.75mm

14,000 (14.8 MJ/h)

1.05mm

13,000

(13.7 MJ/h)

Center (GC901M)

2.15mm

20,000 (21.1 MJ/h)

1.22mm

19,000

(20 MJ/h)

 

 

 

 

 

 

 

 

 

 

 

 

GAS SUPPLY CONNECTION

A manual valve must be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance. (In Massachusetts

such shutoff devices should be approved by the Board of State Examiners of Plumbers & Gas Fitters).

This appliance can be used with either LP gas or Natural gas. It is shipped from the

factory adjusted for use with Natural gas.

For use with a gas pressure regulator. The regulator supplied can be set for either LP gas or Natural gas and must be used with this appliance. It has a 1/2" NPT thread.

Gas connection to the product must use the elbow supplied (it has a 1/2" NPT external thread).

Ensure the blue washer (supplied) is located between the elbow and the product inlet. Failure to use this will cause the product to leak.

Instructions for converting the regulator between NG and LP

1.Unscrew the cap from the regulator.

2.Check the orientation of the plastic conversion plug, and if necessary, unscrew, turn over and screw back in (wide section away from cap for LP and against cap for NG - see diagram below for appropriate orientation.

3.Replace regulator cap.

4.Test gas pressure (test point provision on side of regulator). When converting the regulator for different settings, the function of the regulator must be checked at a pressure at least 1" WC (0.036 p.s.i.) above the specified manifold pressure.

(Note: this diagram is of GC36 but is

Blue Washer

similar for GC901 and GC901M).

LP

NG

Image 4
Contents Installation Information Product & Cutout Dimensions Before YOU StartGC36 GC901/MPreparing the Cutout GC901 / GC901MChecking the GAS Type GAS Supply ConnectionBurners NG Orifice LP Orifice Instructions for converting the regulator between NG and LPConversion to Different GAS Type Testing and SettingTo change the orifices Minimum Setting or Turndown