CHECKING THE GAS TYPE
PAGE 4 OF 6
GC36
Burners | NG Orifice | NG |
| LP Orifice | LP |
|
| (mm) | BTU (MJ/h)@ | (mm) | BTU (MJ/h)@ | ||
|
| 0.15psi (4”H20) |
| 0.41psi (11”H20) | ||
RH Rear | 1.3mm | 8,000 | (8.4 MJ/h) | 0.8mm | 8,000 | (8.4 MJ/h) |
LH Rear | 1.3mm | 8,000 | (8.4 MJ/h) | 0.8mm | 8,000 | (8.4 MJ/h) |
RH Front Simmer | 0.85mm | 3,500 | (3.47 MJ/h) | 0.55mm | 4,000 | (4.2 MJ/h) |
LH Front Wok | 1.75mm | 13,000 (13.7 MJ/h) | 1.05mm | 13,000 (13.7 MJ/h) | ||
Center | 1.45mm | 9,500 | (10 MJ/h) | 0.85mm | 9,500 | (10.0 MJ/h) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GC901 / GC901M
Burners | NG Orifice | NG | LP Orifice | LP |
|
| (mm) | BTU (MJ/h)@ | (mm) | BTU (MJ/h)@ | |
|
| 0.15psi (4”H20) |
| 0.41psi (11”H20) | |
RH Rear | 1.3mm | 8,000 (8.4 MJ/h) | 0.8mm | 8,200 (8.7 MJ/h) | |
LH Rear | 1.1mm | 5,800 (6.1 MJ/h) | 0.7mm | 5,700 (6.0 MJ/h) | |
RH Front Simmer | 0.85mm | 3,000 (3.2 MJ/h) | 0.55mm | 3,500 (3.7 MJ/h) | |
LH Front | 1.3mm | 8,000 (8.4 MJ/h) | 0.8mm | 8,200 (8.7 MJ/h) | |
Center (GC901) | 1.75mm | 14,000 (14.8 MJ/h) | 1.05mm | 13,000 | (13.7 MJ/h) |
Center (GC901M) | 2.15mm | 20,000 (21.1 MJ/h) | 1.22mm | 19,000 | (20 MJ/h) |
|
|
|
|
|
|
|
|
|
|
|
|
GAS SUPPLY CONNECTION
A manual valve must be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance. (In Massachusetts
such shutoff devices should be approved by the Board of State Examiners of Plumbers & Gas Fitters).
This appliance can be used with either LP gas or Natural gas. It is shipped from the
factory adjusted for use with Natural gas.
For use with a gas pressure regulator. The regulator supplied can be set for either LP gas or Natural gas and must be used with this appliance. It has a 1/2" NPT thread.
Gas connection to the product must use the elbow supplied (it has a 1/2" NPT external thread).
Ensure the blue washer (supplied) is located between the elbow and the product inlet. Failure to use this will cause the product to leak.
Instructions for converting the regulator between NG and LP
1.Unscrew the cap from the regulator.
2.Check the orientation of the plastic conversion plug, and if necessary, unscrew, turn over and screw back in (wide section away from cap for LP and against cap for NG - see diagram below for appropriate orientation.
3.Replace regulator cap.
4.Test gas pressure (test point provision on side of regulator). When converting the regulator for different settings, the function of the regulator must be checked at a pressure at least 1" WC (0.036 p.s.i.) above the specified manifold pressure.
(Note: this diagram is of GC36 but is
Blue Washer | similar for GC901 and GC901M). | LP | NG |