6 | electrical connection |
WARNING
TO AVOID ELECTRICAL SHOCK
HAZARD, BEFORE INSTALLING THE APPLIANCE, SWITCH POWER OFF AT THE SERVICE PANEL AND LOCK THE PANEL TO PREVENT THE POWER F R O M B E I N G S W I T C H E D O N ACCIDENTALLY.
This appliance must be connected to a grounded, metallic permanent wiring sys- tem or a ground connector should be connected to the ground terminal or wire lead on the appliance.
This appliance is manufactured with a frame connected, green or bare ground wire. Connect the appliance cable to the junction box through the CSA or
power supply
CONNECT WITH COPPER WIRE ONLY
✓ The flexible (4’) armoured cable should be connected directly to the junction |
box. |
✓ Do not cut the conduit. |
✓ A CSA or |
✓ Do not ground to a gas pipe. |
✓ Do not have a fuse in the grounding or neutral circuit. |
✓ Fuse both supply (phase) lines. |
Junction box
Red wires
White wires
Green & yellow
wire
(or green wire)
Black wires
CSA or
✓ A time delay fuse or circuit breaker is recommended. |
✓ Connect directly to the fused disconnect (or circuit breaker box) through flexible, |
armored or |
✓ If codes permit and a separate grounding wire is used, it is recommended that |
a qualified electrician determine that the grounding path and wire gauge is in |
accordance with local codes. |
If the appliance is to be completely enclosed in a cabinet, feed the appliance cable through the opening in the cabinet. Make the electrical connection follow- ing the appropriate steps for your installation.
1. | Disconnect the power supply. |
2. | Remove the junction box cover. |
3. | Connect the appliance cable to the junction box through the CSA or |
Fig. 6.1
power supply
| duit connector. |
4. | Connect the two black wires together with |
5. | Connect the two red wires together with |
6. | Connect electrical connection according to local codes and ordinances. |
If local codes PERMIT connecting
Junction box
Red wires
Green & yellow
wires
(or green wires)
White wires
Black wires
CSA or
7.Crimp the green & yellow (or green) and white oven wires.
8.Connect the crimped green & yellow (or green) and white oven cable wires to the neutral (white) wire in the junction box (Fig. 6.1).
9.Replace the junction box cover.
OR If local codes DO NOT PERMIT connecting
7.Connect white oven cable wire to neutral (white) wire in junction box (Fig. 6.2).
8.Connect the green & yellow (or green) grounding appliance cable wire to a grounded wire in the junction box.
9.Replace the junction box cover.
Fig. 6.2
OR If connecting to a four-wire electrical system:
7.Connect white oven cable wire to neutral (white) wire in junction box (Fig. 6.2).
8.Connect the green & yellow (or green) appliance cable wire to the green & yellow (or green) grounding wire in the junction box.
Do NOT connect the green & yellow (or green) appliance cable wire to neutral (white) wire in junction box.
9.Replace the junction box cover.