GE TPJ24BR, TPJ24PR, TPJ24PF, TFJ28PR, TFJ30PF, TFJ30PR, TFJ22PR Specifications, Freezer Performance

Page 11

SPECIFICATIONS

 

 

 

UNITS

TFJ30PF

TFJ30PR

TFJ28PF

TFJ28PR

TFJ25PR

TPJ24PF

TPJ24PR/BR

TFJ22PR

TFJ20JR

USEFUL

TOTAL

 

(L)

806

806

764

 

764

 

686

 

630

 

630

588

531

 

VOLUME

FREEZER

 

(L)

301

301

284

 

284

 

243

 

229

 

229

175

175

 

 

FRESH FOOD

 

(L)

505

505

480

 

480

 

443

 

401

 

401

413

356

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL

VOLTAGE

 

(V)

 

 

 

 

SINGLE PHASE 100/100

 

 

 

 

POWER

FREQUENCY

 

(Hz)

 

 

 

 

 

50/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SOURCE

MOTORS

 

(W)

247/238

247/238

247/238

 

247/238

 

252/245

 

248/233

 

248/233

243/231

241/228

 

 

HEATERS

 

(W)

675/675

675/675

675/675

 

675/675

 

675/675

 

675/675

 

675/675

595/595

595/595

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVG MONTHLY ELECTRICAL

 

 

86/89

 

 

 

 

81/81

 

 

 

81/80

71/73

77/78

 

CONSUMPTION (KWH/MON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING METHOD AND

 

 

COLD AIR CIRCULATION TYPE (INDIRECT COOLING)

 

 

 

FREEZER CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER COOLING

 

 

 

FORCED AIR (FAN COOLED CONDENSER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEFROST CONTROL

 

 

 

 

 

AUTO START - AUTO STOP

 

 

 

 

DEFROST WATER REMOVAL

 

 

 

 

FORCED AIR EVAPORATION

 

 

 

 

AUTOMATIC ICEMAKER

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOBILITY WHEELS

 

 

 

 

 

 

ATTACHED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUILT-IN

 

 

 

 

 

 

 

 

POSSIBLE

 

 

 

 

 

 

DOOR REVERSIBILITY

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL RATING

 

(A)

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WEIGHT

 

 

(Kg)

168

168

163

 

163

 

143

 

159

 

159

132

123

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CORD LENGTH

 

(M)

 

 

 

 

 

2.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Values for useful internal volume and the Electrical Standard Values are based on the Japanese Industry Standard (JIS C9607).

*Values separated by “/” indicate 50 Hz on left and 60 Hz on right. Others indicate common 50 Hz and 60 Hz.

Freezer Performance

This freezer/refrigerator is “Four Star” coded.

Performance of freezer is classified by codes.

Each code indicates the performance capability according to the regulation delineated in the Japanese Industry Standard (JIS C9607). The regulation defines the test conditions for measuring the freezing-load temperature (food temperature). The following table shows the test results:

CODE

FREEZING-LOAD TEMP.

FROZEN FOOD PRESERVATION

 

(FOOD TEMPERATURE)

ESTIMATED TIME

 

 

 

 

Below -6°C.

Approx. 1 week

 

Below -12°C.

Approx. 1 month

or

Below -18°C.

Approx. 3 months

 

 

 

Read Before Using

10

Image 11
Contents Operations Guide Do not Instructions for Safe OperationDo not Disassemble Wipe Plug CleanWhen Dirty Clean PlugShort Circuit Connect Grounding ConnectingDo not Install Malfunction orRemove Gasket IgnitionDo not USE Attach Shelves Securely Installation WarningPower Plug Prevent from Toppling OverKeep DRY PossibilityOr Fire Do not Damage Provide Operations Guide Do not TouchTFJ28PF, TFJ30PF, TPJ24PF Part NamesTFJ20JR Freezer Performance SpecificationsTPJ24PF TPJ24PR TPJ24BR External DimensionsExternal Dimensions Refrigerator should be installed on a firm and level floor Instructions for InstallationInstructions for Operation Refrigerator Compartment Operation of Temperature Control DialsSET AT Position 5 for Normal USE Freezer CompartmentHow to Prevent Freezing Interior Temperature ControlAdditional Cooling on Refrigerator Compartment Side Normal OperationSmall Amount of Food is Stored Additional Cooling on Freezer Compartment SideDispensing ICE Cubes Operation of the Custom DispenserOperation of the Custom Dispenser Removing the ICE Bucket Operation of Icemaker Automatic ICE-MAKING ApparatusFreezer Compartment Shelf Utilizing the Interior SpaceRefrigerator Compartment Shelves High Humidity Vegetable Compartment Utilizing the Interior SpaceCHILLING/VEGETABLE Compartment Adjustable Height Door PocketWine Rack QUICK-SERVE Shelf with Serving DishesFreezer Air Lift to Access Lower When Finished KEY to SET DOOR-LEFT-OPEN Warning Electronic Monitor & Diagnostic SystemRefrigerator Interior Temperature Monitor DOOR-LEFT-OPEN MonitorSelection Touch KEY Indicator Light for Normal OperationSystem CHECK/RESET KEY Malfunction Diagnosis Code Display WindowIcemaker Malfunction Automatic Icemaker CI Power Source Malfunction PFFreezer Compartment Malfunction FF Storage of Food Storage of FoodBasic Things to Know about Home Freezing Methods of Selecting and Using STORE-BOUGHT Frozen FoodsWhat to Know about Frozen Foods Care and Cleaning of Refrigerator SELF-DIAGNOSIS During Warranty Period Warranty and AFTER-SERVICE Please Read CarefullyInspection of Older Model Refrigerators Are these symptoms present?