GE TMW-800T, TMW-1100EC manual Knob VPC, Knob Timer, Coupler Timer POM, Coupler VPC Knob POM

Page 52

5. To remove control panel parts.

REF NO.

PART CODE

PART NAME

DESCRIPTION

Q’TY

REMARK

B01

3513405450

KNOB VPC

ABS SG-0760D, SG-176

1

 

B02

3513405460

KNOB TIMER

ABS SG-0760D, SG-175

1

 

B03

3511603930

DECORATOR C-PANEL

STS T0.6

1

 

B04

3516003950

SPECIAL DOUBLE TAPE

SI-161 T0.15

1

 

B05

3516726320

CONTROL PANEL

ABS VT-0826, AF-348

1

 

B06

3515101600

SPRING FLAT

SUS 301 T0.5

1

 

B07

7122401211

SCREW TAPPING

T2S TRS 4*12 MFZN

1

 

B08

3518206300

TIMER

NT10MKD01U-P

1

 

B09

7122401211

SCREW TAPPING

T2S TRS 4*12 MFZN

2

 

B10

3517400400

COUPLER TIMER

POM

1

 

B11

3517400500

COUPLER VPC KNOB

POM

1

 

1)Remove the screw which secure the control panel, push up two snap fits and draw forward the control panel assembly.

2)Remove two screws which secure the timer assembly.

3)Remove the timer assembly.

4)Pull out the timer knob from the timer.

5)Pull out the timer coupler from the timer.

6)Remove the screw which secure the V.P.C coupler.

7)Pull out the V.P.C coupler, V.P.C knob and flat spring from the control panel.

8)Reverse the above steps for reassembly.

50

Image 52
Contents Turbo Air Inc Microwave Oven Table of Contents TMW-800T / TMW-800TC Safety and Precautions For Safe Service ProceduresFor Safe Operation Microwave RadiationSpecifications Outer Dimension Feature DiagramSafety interlock system External View ElectricalControl Panel External View Mechanical 560 483 344Installation Leave space behind and sideWattage output chart Operations and Functions ElectricalVariable power setting Approximate Percentage Variable power cookingOperations and Functions Mechanical Disassembly and Assembly ShortTo remove cabinet Part Code Part Name Description To reduce gap located on part ‘A’ REF no Part Code Part Name Description ’TY Remark Part Code Part Name Description ’TY Magnetron To remove wind guide assembly Primary interlock switch Secondary interlock switch and interlock monitor switchAdjustment Adjustment stepsTrouble Shooting Guide ConditionCheck Result CauseCheck Condition Check Result Cause RemedyCondition Check Result Relay RY1Not show Interlock Mechanism and Adjustmentmechanical No Continuity Replace power supply cord YES Heating time for power output ProcedureMeasurement and Test Microwave Radiation Test High voltage transformer High voltage capacitorHigh voltage diode MagnetronWiring Diagram TMW-1100EC Wiring Diagram TMW-1100E Wiring Diagram TMW-1100MC Wiring Diagram TMW-1100M Printed Circuit Board Low voltage transformer checkVoltage Check Check Point RemarkMP1 MP2 Measure pointPoint State Relay 2 on 5VDC GND Relay 2 OFF 12VDC Point State Relay 1 on 5VDC GNDGND 12VDC Point StateC.B. Circuit Diagram C.B. Location no Name Symbol Specification Part Code ’TY Exploded View and Parts List Electrical Total AssemblyPart Code Part Name Description QTY Exploded View and Parts List Mechanical CONTROL-PANEL AS KOR-1P55BA Power Consumption Grill Combination Microwave Energy Output Power SupplyTMW-800T / TMW-800TC Outer Dimension Feature Diagram External ViewSteady, flat location Operations and Functions Disassembly and Assembly REF no Part Code Part Name Description ’TY Page Knob Timer Coupler Timer POMKnob VPC Coupler VPC Knob POMHigh voltage circuit wiring To remove magnetron Noise FilterOnly KOR-63555B Interlock Mechanism and Adjustment Trouble Shooting Guide Does the oven lamp light? no Does the turntable turn? Measurement of the Microwave Power Output Procedures Microwave Radiation TestComponent Test Procedure Wiring Diagram TMW-800TC Wiring Diagram TMW-800T Power Supply Single Phase onlyExploded View and Parts List Total AssemblyDoor AS Control Panel ASCabinet Secc T0.5 Cavity ASAbout this Manual

TMW-1100MC, TMW-1100E, TMW-1100M, TMW-800TC, TMW-1100EC specifications

The GE TMW series of gas turbines, particularly the TMW-800T, TMW-1100EC, TMW-800TC, TMW-1100M, and TMW-1100E, represent some of the most advanced technology in power generation, designed for efficiency and reliability.

The TMW-800T is renowned for its compact design and high efficiency, making it ideal for both utility and industrial applications. This turbine boasts a modular design that facilitates ease of maintenance and installation, while its advanced aerodynamics contribute to enhanced performance and reduced emissions. Additionally, its ability to operate on multiple fuel types allows for greater operational flexibility.

Similarly, the TMW-1100EC model offers enhanced power output and efficiency. It incorporates advanced combustion technology that minimizes nitrogen oxide emissions, complying with increasingly stringent environmental regulations. The electronic control system in this model allows for superior performance management and load-following capabilities, ensuring optimal performance under varying demand.

The TMW-800TC variant focuses on achieving high thermal efficiency while maintaining significant output levels. Its cooling technologies, including advanced blade cooling techniques and heat recovery systems, enable this turbine to sustain higher operating temperatures, improving its overall efficiency. This design is particularly beneficial in combined cycle power plants, where waste heat can be repurposed to generate additional electricity.

The TMW-1100M is particularly noteworthy for its versatility and adaptability in a wide range of applications, from cogeneration to standalone power generation. Its design includes robust materials and components engineered to withstand rigorous operating conditions, ensuring longevity and reliability, which is essential for industrial users who depend on consistent power availability.

Lastly, the TMW-1100E emphasizes operational efficiency through its advanced control systems and intelligent monitoring. This turbine is equipped with sensors and software that provide real-time data analytics, allowing for proactive maintenance and operational optimization. This technology not only enhances performance but also contributes to lower operational costs.

In summary, the GE TMW gas turbine series, with their various models, exemplify cutting-edge technology and engineering. Their main features include high efficiency, reduced emissions, operational flexibility, and advanced control systems, making them a preferred choice for power generation in both industrial and utility markets. Their adaptability to different fuels and operational environments further solidifies their stance as leading solutions in the gas turbine landscape.