GE 42, 48 owner manual Performance Data Sheet, Operating Specifications, Special Notices

Page 42
Standard No. 53: Health Effects
Chemical Reduction Unit Lead and Atrazine Reduction Lindane and 2,4-D Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction

Performance Data Sheet

SmartWater Filtration System

GWF / HWF Cartridge

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*

(100% safety factors built in for unmetered usage)

Standard No. 42: Aesthetic Effects

Parameter

USEPA

Influent

Effluent

 

% Reduction

Min. Required

 

MCL

Challenge Concentration

Average

 

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L + 10%

0.02 ppm

 

0.05 ppm

98.90%

97.37%

> 50%

T & O

 

Particulate**

at least 10,000 particles/mL

3,978

 

7,800

98.00%

96.10%

> 85%

Standard No. 53: Health Effects

Parameter

USEPA

Influent

Effluent

% Reduction

Min. Required

 

MCL

Challenge Concentration

Average

Maximum

Average

Minimum

Reduction

Turbidity

1 NTU***

11 + 1 NTU***

0.07 NTU

0.1 NTU

99.71%

99.59%

0.5 NTU

Cysts

99.95% Reduction

Minimum 50,000 L

26

55

99.97%

99.95%

> 99.95%

Lead at pH 6.5

15 ppb

0.15 mg/L + 10%

1 ppb

1 ppb

99.37%

99.37%

0.010 mg/L

Lead at pH 8.5

15 ppb

0.15 mg/L + 10%

1.8 ppb

4.3 ppb

98.8%

97.13%

0.010 mg/L

Lindane

0.0002 ppm

0.002 mg/L + 10%

0.00005 ppm

0.00005 ppm

91.93%

91.93%

0.0002 mg/L

Atrazine

0.003 ppm

0.009 mg/L + 10%

0.002 ppm

0.003 ppm

76.19%

64.28%

0.003 mg/L

2,4-D

0.100 ppm

0.210 mg/L + 10%

0.042 ppm

0.090 ppm

84.89%

67.63%

0.07 mg/L

Asbestos

99%

107 to 108 fibers/L;

0.32 MFL/ml

1.2 MFL/ml

99.95%

99.82%

99%

 

 

fibers greater than

 

 

 

 

 

 

 

10 micrometers in length

 

 

 

 

 

*Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C

**Measurement in Particles/ml. Particles used were 0.5-1 microns

***NTU=Nephelometric Turbidity units

Operating Specifications

Capacity: certified for up to 500 gallons (1135 l); up to twelve months for all models

Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock

Temperature: 33–100ºF (0.6–38ºC)

Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

Flush new cartridge at full flow for 3 minutes to purge out trapped air.

Replace cartridge when flow becomes too slow.

Special Notices

Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.

Check for compliance with the state and local laws and regulations.

Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.

System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:

Standard No. 42: Aesthetic Effects

Chemical Unit

Taste and Odor Reduction

Chlorine Reduction

Mechanical Filtration Unit

Particulate Reduction, Class I

NSF®

Manufactured for: General Electric Company, Louisville, KY 40225

42

Image 42
Contents 49-60341-1 11-04 JR Serial #Safety Precautions Before You Throw Away Your Old Refrigerator or Freezer RefrigerantsGEAppliances.com HOW to Connect Electricity Performance Air Flow System About the water filter. on some models When to Replace the FilterInstalling the Filter Cartridge Water Filter CartridgeSpillproof Shelves and Freezer Shelves About the shelves and binsRefrigerator Door Bins and Freezer Door Bins To remove shelvesAbout the refrigerator doors Refrigerator DoorsDoor Alignment About the drawers and baskets Adjustable Humidity DrawersHow to Remove and Replace the Drawers and Freezer Baskets Fruit and Vegetable DrawersAbout the ice and water dispenser and automatic icemaker Ice Storage BinAutomatic Icemaker To Use the Dispenser Door AlarmAbout the ice and water dispenser Locking the Dispenser Quick IceCare and cleaning of the refrigerator Cleaning the OutsideCleaning the Inside Preparing for Vacation Preparing to MoveRefrigerator Compartment-Lower Light Replacing the light bulbsRefrigerator Compartment-Upper Light Freezer CompartmentBefore YOU Begin Read Carefully Keep These InstructionsRead these instructions completely and carefully Hardware Supplied Materials RequiredTools Required Water and Electrical Locations Installation Space Dimensions and ClearancesAdditional Specifications Cutout depth must be 24″Top View Door Swing Factory setting Scale Top View Customization Basics ″ Framed Panel Dimensions Important Note Dispenser Trim″ Framed Custom Panel Option ″ FULL-WIDTH Overlay Custom Panel Option″ Framed Custom Wood Panels Fresh Food PanelGrille Panel Upper Freezer PanelLower Freezer Panel ″ FULL-WIDTH Overlay Custom Panels Finished Backer PanelLower Freezer Panel Spacer Assembly Flooring Side PanelsGrounding the Refrigerator IMPORTANT-Please read carefullyRemove Packaging Install Water Line Shut off the main water supply2A Water Line Installation with a Reverse Osmosis System Install Side PanelsInstall ANTI-TIP Brackets Connect Power Level RefrigeratorAdjust Door Swing Install Grille PanelRefrigerator must be secured to prevent tipping Install Door Panels Reinstall Handles Install Door PanelsInstall 1/4″ Decorative Panels Remove Handles ″ Custom Decorative PanelsCopper Tubing Turn on the PowerConnect Water Supply GE SmartConnect TubingInstall Toekick Start IcemakerDoor Alignment Normal operating sounds Hummm WhooshTroubleshooting tips… Slow ice cube freezing See Care and cleaningSmall or hollow cubes Water dispenser doesFreezer Refrigerator has odor Temperatures are OKOrange glow Moisture forms onConsumer Warranty GE Will Replace What GE Will Not CoverGeneral Installation/Operation/Maintenance Requirements Performance Data SheetOperating Specifications Special NoticesWater Treatment Device Certificate Number Operating Instructions Safety Instructions We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration Fonctionnement Avertissement RéfrigérantsRaccordement Électrique Electromenagersge.caLes commandes de température Système de circulation d’airFiltres de remplacement Remplacement du filtreInstallation de la cartouche du filtre à eau Cartouche du filtre à eauPour enlever un bac Soulevez le bac vers Clayettes et bacsClayettes anti-déversements et clayettes de congélateur Enlèvement des clayettesLes portes du réfrigérateur Portes du réfrigérateurAlignement des portes Les tiroirs et les paniers Tiroirs à fruits et légumesTiroirs avec humidité variable Pour enlever Bac à glaçonsMachine à glaçons automatique Pour remettre en placeGlace rapide Le distributeur d’eau et de glaçonsPour utiliser le distributeur Verrouillage du distributeurEntretien et nettoyage du réfrigérateur Nettoyage de l’extérieurNettoyage de l’intérieur Départ en vacances DéménagementCompartiment réfrigérateur-lampe inférieure Remplacement des ampoulesCompartiment réfrigérateur-lampe supérieure Compartiment congélateurAvant DE Commencer Lire ces instructions complètement et soigneusementQuincaillerie Fournie Matériel NécessaireOutils Nécessaires Espace Pour L’INSTALLATION Dimensions ET Espaces LibresPanneau de soutien De 19 mm 3/4 po Éléments DE Personnalisation Dimensions DES Panneaux Encadrés DE 6 mm 1/4 po Option DE Panneau Personnalisé Encadré DE 19 MM Panneaux DE Bois Personnalisés Encadrés DE 19 MM Panneau de Compartiment pourAliments frais Panneau de grille Panneau supérieur pour le congélateurPanneau inférieur pour le congélateur Panneaux Personnalisés Couvrants Pleine Largeur DE 19 MM Panneau de compartiment pour aliments fraisPanneau inférieur pour le congélateur SOL Panneaux LatérauxMise À LA Terre DU Réfrigérateur IMPORTANT-À lire attentivementEnlèvement DE L’EMBALLAGE Plat SUR LE SOL Pour Enlever LA PaletteInstallation DE LA Conduite D’EAU Coupez l’alimentation d’eau principaleInstallez Panneaux Latéraux Installez PattesANTI-BASCULEMENT Mise EN Place Dans L’ESPACE D’INSTALLATION Branchement DE ’ALIMENTATION ÉlectriqueMise À Niveau DU Réfrigérateur Installation DU Panneau DE LA Grille Fixation DU Réfrigérateur AUX ArmoiresRepose des poignées Panneaux décoratifs sur mesure de 19 mm 3/4 poBranchement DE ’ALIMENTATION D’EAU Mise Sous TensionInstallation DE LA Plinthe Mise EN Marche DE LA Machine À GlaçonsAlignment DES Portes Bruits normaux de fonctionnement HummmConseils de dépannage… Bourdonnement La machine à glaçonsNe fonctionne pas FréquentLe distributeur d’eau Consultez Installation de la conduite d’eauConsultez Remplacement des ampoules Fonctionne, mais neLes températures sont Un signal sonore’arrête jamais mais NormalesGarantie DU Client Feuillet de données relatives à la performance Norme no 42 Effets esthétiquesPage Page Page Service de réparations Prolongation de garantieInscrivez votre appareil électroménager Schedule Service Consumer Support
Related manuals
Manual 16 pages 56.45 Kb

48, 42 specifications

The GE 42 and GE 48 are two state-of-the-art aircraft engines produced by General Electric, renowned within the aerospace sector for their advanced technologies and high-efficiency performance. These engines, designed primarily for commercial and military aviation, exemplify GE's commitment to innovation in the world of jet propulsion.

One of the distinguishing features of the GE 42 is its high bypass ratio, which allows for reduced fuel consumption and lower emissions during operation. This characteristic directly contributes to the engine's environmental efficiency, making it a favorite among airlines looking to minimize their carbon footprint while maximizing fuel economy. The GE 42 is equipped with advanced composite fan blades and fan cases, which contribute to its robust performance while maintaining a lightweight structure.

On the other hand, the GE 48 boasts similar high bypass ratio features but comes with slightly enhanced performance metrics suitable for larger aircraft. The GE 48 utilizes cutting-edge digital technologies, including predictive maintenance systems, enabling real-time monitoring of engine performance. This capability allows operators to make informed decisions about maintenance schedules and operational efficiency.

Both engines employ the latest in additive manufacturing, allowing for complex parts to be produced with a high degree of precision and reduced waste. This not only enhances performance but also lowers production costs, ensuring that GE remains competitive in the market. Additionally, both the GE 42 and GE 48 feature improved aerodynamics, with specially designed turbine blades that optimize airflow, thereby boosting overall efficiency.

The durability of these engines is another notable highlight. They are designed to withstand extreme operational conditions, ensuring reliability whether used for long-haul flights or military missions. Engine life extends through advanced materials that can endure high temperatures and stresses, making them suitable for various applications.

In conclusion, the GE 42 and GE 48 stand out in the aviation industry for their innovative technologies and characteristics. Their high bypass ratios, use of advanced materials, digital monitoring systems, and aerodynamic designs make them exemplary choices for modern aviation needs, catering to both commercial and military sectors while focusing on sustainability and performance. As aviation technology continues to evolve, these engines remain at the forefront, embodying the future of flight.