OPERATION PRINCIPLES BY PARTS OF CIRCUIT
5-11) OPTION Circuit
●This circuit operates with the initial power on, uses DIODE (1N4148) or JUMPER WIRE.
To modify option circuit, Power must be turned off before modification and turned on after the modification. Refer to the table below, the default factory values are highly recommended unless exceptional cases.
OP11, OP12
OP11 |
| OP12 | MODEL | FUNTION |
|
|
|
|
|
○ |
| ○ | RS2*11 | No Cruch, 3 Step, Light |
○ |
| ● | RS2*21 | Cruch, 3 Step, Light |
● |
| ○ | RS2*31 | Cruch, 5 Step, P/F, L/T Lock, Filter, Indicator |
* ● Jumper USE | OP2 < Water Fill Time Control Option > |
| ||
|
|
|
|
|
D601 |
| D602 | Fill Time | Remark |
|
|
|
|
|
● |
| ● | 5 Sec |
|
|
|
|
|
|
● |
| ○ | 6 Sec | Flow Sensor Not USE |
|
|
|
| |
○ |
| ● | 7 Sec | |
|
| |||
|
|
|
|
|
○ |
| ○ | 10 Sec |
|
|
|
|
| |
* ● Diode(1N4148) USE |
|
|
25