Appendix Ⅰ(Reference for circuit diagnostics)
Ref.1) Measure Load Terminals
Turn off Power, disassemble Housing connected to MAIN PCB CN70,71,72 and measure followings
LOAD | TERMINALS PCB CASE | VALUE | DEFECTS | OTHERS |
|
|
|
|
|
1) DEFROST HEATER | CN71 ⑪ & ③ | 0Ω | THERMAL FUSE, HEATER, WIRE SHORT THERMAL |
|
2) ICE PIPE HEATER | ∞Ω | BIMETAL, HEATER, WIRE CUT |
| |
|
|
| ||
DISPENSER HEATER | CN72 ① & ③ | 0Ω | HEATER, WIRE SHORT |
|
∞Ω | HEATER, WIRE CUT OR HOUSING SLIPPED AWAY |
| ||
|
|
| ||
WATER VALVE | CN70 ⑤ & | 0Ω | COIL, WIRE SHORT |
|
ICE MAKER | CN71 ③ | ∞Ω | COIL, WIRE CUT |
|
WATER VALVE | CN70 ⑦ & | 0Ω | COIL, WIRE SHORT |
|
DISPENSER | CN71 ③ | ∞Ω | COIL, WIRE CUT |
|
AUGER MOTOR | CN70 ① & | 0Ω | COIL, WIRE SHORT |
|
CN71 ③ | ∞Ω | COIL, WIRE CUT |
| |
|
| |||
CUBE SOLENOID | CN70 ③ & | 0Ω | COIL, WIRE SHORT |
|
CN71 ③ | ∞Ω | COIL, WIRE CUT |
| |
|
| |||
COMP. FAN MOTOR | CN71 ⑦ & ③ | 0Ω | MOTOR, WIRE SHORT MOTOR, WIRE CUT OR |
|
∞Ω | HOUSING SLIPPED AWAY |
| ||
|
|
| ||
|
|
|
|
|
F FANMOTOR | CN71 ① & ③ | 0Ω | MOTOR, WIRE SHORT |
|
∞Ω | MOTOR, WIRE CUT OR HOUSING SLIPPED AWAY |
| ||
|
|
|
31