OPERATING INSTRUCTIONS & INSTALLATION
4) At Initial Power On
4-1) At initial power on of fridge product when temperature in the freezer compartment is not lower than 14 and temperature in the fridge compartment is not lower than 50 , if power freezing and power cool functions are selected, operation will be different from the above functions.
4-2) In this case, R-FAN turns off for a little while if power freezing is selected whereas F-FAN turns off for a little while if power cool is selected. This operation works only once at time of initial power on.
4-3) This function is to powerfully cool down only the ROOM preferably wanted by customer when using fridge product for first time while temperature in product would be rather high.
3-4) Lock Function
The lock function is set and canceled by the ICE-OFF and the LIGHT BUTTONS.
-Lock function is set if ICE-OFF BUTTON and LIGHT BUTTON are simultaneously depressed for 3 seconds under lock cancellation status.
-If the lock function has been set, then the ice selection function, functions related to the dispenser, and all other functions are to be held because temperature control / power functions / Arctic Select Zone function / Fresh Select Zone function / ice selection function etc. maintain their current setting conditions. (when the lock LED is on.) This function has been developed to prevent random operation by children (infants).
-If to cancel lock function under condition where lock function has been selected, then lock function may be relieved if ICE-BUTTON and LIGHT BUTTON are simultaneously depressed for 3 seconds so as to be
able to operate on front panel.
If the lock function has been canceled, the lock LED turns off and you may perform key selection. We recommend you to use lock function for user's necessity, and to be well acquainted with it in advance because this function may bring about customer's NON-SENSE CALL.
3-5) Functions in Case Where Ice Dispenser and Water Dispenser Have Been Attached (External Type)
This function applies only for model where ice maker and ice/water dispenser have been attached.
1)CUBE / CRUSHED / ICE OFF Selection Function
1-1) This function is to operate in CUBE/ CRUSHED / (ICE OFF function according to selection upon DISPLAY by user, which selection is made use by each corresponding button.
1-2) CRUSHED is automatically selected at initial POWER ON of the refrigerator product.
1-3) Water is extracted by operating the WATER SOLENOID VALVE under the condition of WATER LEVER ON.
1-4) Operate by using AUGERMOTOR and cubic ice solenoid the ice that has been made in ice tray when drawing out ice after selecting the CUBE.
1-5) Operate by using only AUGER MOTOR the ice that has been made in ice tray when drawing out ice after selecting the CRUSHED .
1-6) ICE-MAKER stops operation if function of ICE OFF has been selected. After if cubic / crushed are selected, function of ice off is automatically halted so as to facilitate again execution of ice maker function that was in use before ice off.
18