OPERATING INSTRUCTIONS & INSTALLATION
This
1)Initial Operation
This is operation at initial “power on” or at that after “power off” due to electricity interruption which operation is to restore to horizontality by revolving ice extraction motor.
Reverse rotation : CCW
Forward rotation : CW
(1)
(2)
(3)
Ice extraction
S/W
Signal generated by ice inspection lever when returning to horizontal position
Instrumental lock position
Horizontal position
Interval about
880ms
S/W cognition debounce is taken about 2 seconds at time of reverse rotation of interval (1) so as not to mistake this interval as horizontal position
Instrumental lock position
Maximum torsion point
Figure- Horizontal movement operation at initial power on of the product (referes to ice extraction S/W)