Samsung RM255BASB, RM255BABB Operating Instructions & Installation, Self-Diagnostics Function

Page 28

OPERATING INSTRUCTIONS & INSTALLATION

3-15) Self-Diagnostics Function

1)Self-Diagnostics Function at Initial POWER ON

1-1) MICOM judges internally by itself within several seconds whether there is any error in temperature sensor if electricity is initially applied to the refrigerator.

1-2) If an inferior sensors are found as the result of Self-Diagnostics operation, all relevant display LEDs are flickering at 0.5 second interval. But no alarm sound is generated separately.

1-3) Under the condition where a display LED flickers due to a bad sensor occurrence, only the Self-Diagnostics function buttons

are recognized (the freezing setting + the Refrigeration setting keys shall be pressed simultaneously for 8 seconds) and normal display does not proceeded while temperature control is executed only by an emergency operation.

1-4) The above status is canceled automatically in case an error with the Self-Diagnostics occurred, if all bad sensors would have been repaired, or if the freezing setting + the Refrigeration setting keys are pressed simultaneously for 8 seconds.

Press the keys simultaneously for 8 seconds.

2)Self-Diagnostics Function during Normal Operation

2-1) If the freezing setting + the Refrigeration setting keys are pressed simultaneously for 6 seconds, during normal refrigerator operation, the temperature-setting display flickers ALLON/OFF with 0. 5 second interval for about 2 seconds.The Self- Diagnostics function is selected when the freezing setting + the Refrigeration settingkeys are pressed simultaneously for about 8 seconds, including the 2 seconds during which theLED repeats ON/OFF..

2-2) When the Self-Diagnostics mode is mode, the buzzer makes a ding-dong sound.

2-3) If the Self-Diagnostics mode is entered, then all LCDs turn off except relevant LCDs where function abnormality arose so as to display their own defect occurrence (cf. Self-Diagnostics Check list below).

2-4) Display of error occurrence returns to normal condition after 30-second duration of error display regardless of repair. (Buzzer sound off ding dong when returning to normal condition)

2-5) Button input is not accepted during Self-Diagnostics execution.

2-6) Among the above Self-Diagnostics items, ICE MAKER SENSOR AND ICE MAKER FUNCTION ERROR CHECKS are only executed in case the user has selected ICE MAKER model option as an external attachment type.

27

Image 28
Contents RM255BARB RM255BASB RM255BABB Authorized Training Center Campuses Important Safety Notice Contents Precautionssafety Warnings Symbols Forbidden Product Specifications This operation instruction covers various models ManualRM25 Model SpecificationAfter packing 386lbs Electric Parts Specification SensorSpecifications Model Dispenser Home Bar Electric ComponentsItems RunningPhotograph Optional Material SpecificationsPart Code Operating Instructions & Installation Temperature Control Operation Digital PanelPower Freeze and Power cool Operation Power Freeze OperationPower cool Operation By in inside function irrespective of current settingAt Initial Power On Lock FunctionAble to operate on front panel Cube / Crushed / ICE OFF Selection FunctionMachine Room F-Fan Motor Delay Function Water Dispenser FunctionLight Operation Load Operation ConditionInitial Operation Reverse rotation CCW Forward rotation CW Ice extractionHorizontal position Interval about 880ms Maximum torsion pointWater Supply Function Ice-Making FunctionIce Extraction Function Water Supply TimeBold numerals indicate relevant ice tray steps Horizontality operation Defrosting Function Defrosting period is fixed to 8 hoursArctic Zone 53.6 62.6Arctic Select Zone Function FunctionOperation Fresh Select Zone FunctionFunction Operation Specification Temp .8 ~ 44.6 of the Fridge compartmentTest KEY Operation startForced Defrosting Function For the R compartmentAlarm Function Communication Error Display FunctionWhen water supply is finished, in the ice maker test mode Display Function at PanelOperating Instructions & Installation Self-Diagnostics FunctionSelf-Diagnostics Checklist BAD Item Trouble StatusError DefrostingSensor of R CR SensorCF-FAN Error CR-FAN ErrorOn Error TroubleLoad Condition Display Function Load Mode Checklist Load Item Load StatusRelevant displays about load status is as follows Changing to Optional Mode Option Setting FunctionKEY Function Value ItemTemperature Change Table for the Freezer Compartment Change for freezer compartmentTemperature Change Table for the Refrigerator Compartment KEYCR Room Temperature Shift Function Case of basic model, the following items cannot be setMaker For Ice Maker Flow sensorDisassembly and Reassembly Removing the Front Leg Cover Door AssyRemoving the Freezer Door Removing the Refrigerator Door Remove two screws holding it to Open the Fresh Select Zone DoorLiner on the right side of the rail To separate it Reattaching the Freezer Door Reattaching the Refrigerator Door Levelling Open the Arctic Select Zone Door ZoneWater line must be connected to drinkable water only Do not overtighten the compression Note nutClose the filter cartridge cover Door Sub Parts Control PanelDoor Handle Door GasketRefrigerator Door Light Switch Refrigerator LightTempered Glass Shelf Plastic Drawers in the RefrigeratorFreezer Door Light Switch Freezer CompartmentsDoor Bin in Freezer Plastic Drawer in FreezerTighten the screws 2 of the ice maker support Ice Dispenser Ice MakerFreezer Light Auger Motor Case Upper DuctworkPartition in the Freezer Screws Pull the upper part of the evaporator cover slightlyEvaporator Fan Motor Evaporator in FreezerFreezer Thermistor Thermistor cover ScrewIce-Maker Thermistor Water TankEvaporator cover in the Refrigerator Evaporator Fan Motor in RefrigeratorEvaporator in Fridge Refrigerator ThermistorDuctwork Thermistor Thermistor cover Fresh /Arctic Select ZoneTM ThermistorUpper Ductwork Machine Compartment Electric Box PCB-MAIN AssySub-condenser Water SolenoidsRemoving the Arctic Select Zone Accessories If power is not on StartNormal Check at the Smps PBA Check Main PCB connectionExchange and repair COMP. Assembly Check connector for Contact failureIf the compressor doesn’t work normally Reference Perform forced defrosting for F R room one at a timeIf the ambient temperature sensor has trouble How To Check Temperature Sensing in the manualIf there is a trouble with self-diagnosissensor failure Check the soldering on the main PCB for Shorts & breaksAlarm Sounds continuouslyrelated to the buzzer If Ding-Dong sounds continuously StartIf Beep sounds continuously Start Gasket, food etcIf the buzzer doesn’t sound Main PCB is normal, buzzer is NormalBuzzer is broken - replace it Replace buzzer or panel PCBIf the panel PCB is not working normally Where the Panel PCB key isn’t selectedIt is a care If fan motor doesn’t working normaly Door S/WDoor Open 0V DC ConditionThese signals will be inputted into Micom Door Open DCIf Ice Cubed or/and Ice Crushed dont work normally If Indoor Lamp of Freezer/Refrigerator doesn’t light Replace Inside lamp Replace or troubleshoot Door S/WIf Water Drawer doesnt work normally Preliminary Check Replace connector Wire and switch Replace connector and wireIf Dispenser LED Lamp doesnt light Failure of panel PCB itselfWiring Diagram Connector Arrangement Main Board Circuitschematic Diagram Conn Ector Arrangement SMP S Board Power BUS A voltage proportional to98.9 93.7 40.0 88.9 38.2 84.2 36.4 79.8 34.6 75.7 32.8 71.868.2 64.7#18 GND0.8V IC75 Input IC75 Output FAN107 Motor Drive Circuit Descriptions Principle of OperationComparison in HIGH/LOW Speed RemarksXAA 13-2 Q & a Problem Possible Causes What To Do Reference InformationProblem Possible Causes What To Do Small or hollow cubesCompressor Sub-condenser Hot Pipe Dryer Step valve Additional InformationSuction Pipe Freezer Refrigerator